Installation & Operation Manual

Copyright © Puretec Ltd 2018

Installation Guide

9.  Restore the water supply and check for leaks. 

10.  Run the system for at least 5 minutes to remove carbon fines. Water may appear 

milky, but this is normal and is only tiny air bubbles that will clear after a short period.

Cartridge Installation/Changeout

1.  Place container under filter in case of drips.

2.  Twist out old cartridge. Discard old cartridge.

3.  Remove packaging from the new cartridge including the yellow cap on top of the 

cartridge. Twist in the new cartridge. Ensure firm seal to head.

 

Replacement cartridge code: 

Puretec

 

QT12R

4.  Reset LED indicator by following instructions on page 6. 

5.   Restore water supply.

6.  Check for leaks, rectifying them, if any, before leaving the unit.

 

After installing cartridges flush unit for 5 - 10 minutes.

Use Guidelines

• 

Minimum operating pressure 100 kPa.

• 

Maximum operating pressure 875 kPa.

• 

Do not allow exposure to temperatures below 3°C.

• 

Maximum operating temperature 38°C.

• 

Maximum flow rate 5 Lpm.

• 

This system must be installed according to local plumbing codes on the cold water line 
- mains only.

• 

Replacement Cartridges: See Cartridge Changeout section

• 

This system requires regular replacement of the filter cartridge to maintain proper 
operation. Varying chlorine, sediment, or organic substance levels may affect 
replacement frequency.

• 

Be sure to change the filter cartridge at least every 11,355 litres or 6 months which 
ever occurs first; or whenever you detect a change in taste, odour, or decrease in flow. 

 

Caution

: Do not use with water that is microbiologically unsafe or of unknown quality 

without adequate disinfection before or after the system.

Содержание QT12

Страница 1: ...S 3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System QT12 For correct operation installation it is essential to observe these instructions JUL2018 ...

Страница 2: ...before or after the system Operation The Puretec QT12 system is designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems for 10 minutes after any period of non use more than 2 days For a period of non use of 2 weeks or more it may be necessary to replace cartridge Cartridge Replacement To maintain the high quality of the...

Страница 3: ...r line and connect the Smart Tee Reinstall the previous connection to the tee valve 3 Connect the pressure limiting multivalve to the Smart Tee with a length of white tubing 4 Choose the best position for the faucet taking into consideration height of jugs etc and also the drainage of any spills Then drill a 012 5mm hole and install the faucet as in step 5 5 To install faucet place the escutcheon ...

Страница 4: ... if any before leaving the unit After installing cartridges flush unit for 5 10 minutes Use Guidelines Minimum operating pressure 100 kPa Maximum operating pressure 875 kPa Do not allow exposure to temperatures below 3 C Maximum operating temperature 38 C Maximum flow rate 5 Lpm This system must be installed according to local plumbing codes on the cold water line mains only Replacement Cartridges...

Страница 5: ...out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure 1 12 6 7 8 10 9 11 3 4 5 2 2 2 No DESCRIPTION 1 Smart Tee M x F x T 2 flexible tubing 3 pressure limiting valve 4 QT12R filter cartridge 5 mounting bracket 6 tube nut and olive 7 tube insert 8 faucet lock nut and washer 9 black plastic...

Страница 6: ...black battery seat from the faucet lever handle see figure 2 2 Install battery into the battery seat positive side up Note red light flashes twice and then followed by the blue light 3 Reinstall battery seat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 min...

Страница 7: ...es 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Will stop bacteria increasing but will not remove them unless II a is passed N A Bacteriostatic II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A II b ...

Страница 8: ... no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the Warranties need to be approved by Puretec to ensure product was not incorrectly used installed or claimed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incu...

Отзывы: