4
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2020
Connecting
Pipework
Isolation
Valve
Pressure
Limiting Valve
Isolation
Valve (recommended)
Outlet
Inlet
Positioning Your Filter
Positioning Your Filter
Choose a location where any water spillage will not cause damage. If a cupboard
is chosen care needs to be taken in case of water spillage or flooding. Make sure
mounting position is solid so that the filter housing stays in position when changing
filters. An isolation valve may be installed immediately prior to the filter to isolate the
filter for changing the cartridge.
Installation Procedure
1. Isolate water supply and relieve pressure by opening a downstream tap.
2. Cut pipe to suit length of required valve and housing installation.
3. Use approved brass, galv/poly plumbing fittings to suit existing pipework. The
female threads on the housing will receive tapered male threads. Thread into
housing head carefully as too much tape or overtightening may cause it to split
WARNING: Use PTFE thread seal tape on all connections. Use of liquid pipe
sealant/dope will void warranty.
4. If using sweated fittings, allow enough time to cool before connecting to the
housing.
5. Securely fix wall mount bracket and pipework with suitable clips. Allow 50mm
clearance under the housing bowl for filter changes.
6. Flush debris from pipework.
7. Install filter cartridge as per cartridge replacement instructions.
Typical Installation