9
OuTPuTS, diSPlay aNd CONNECTiON PurPOSE
Edition of 0
9
.12.2020
06
Fig. 5. Connection of modules to a plasma source without a voltage divider
Fig. 6. Connection of modules to a plasma source without a voltage divider and Arc ok output
Position of DIP
switches of ТНС1-DV1
module
To network switch or PC
Twisted pair
(connector
8Р8С)
NC control console
Plasma source
Arc voltage
Arc transfer
Arc transfer
Control board
Torch ("-")
Product ("+")
Position of DIP
switches of ТНС1-DV1
module
To network switch or PC
Twisted pair
(connector
8Р8С)
NC control console
Measuring
current
transformer
Plasma source
Ignition
Control board
Torch ("-")
Product ("+")