Содержание EAR16NG

Страница 1: ...IFLUE RADIANT GAS FIRE MODEL NUMBERS EAR16NG EAR16P Manual Remote Control Models INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER THIS APPLIANCE MEETS THE REQU...

Страница 2: ...8 Briefing the User 8 USERS GUIDE 9 Useful tips recommendations 9 Operation of your fire 9 Manual Appliances 10 Handset remote models 10 Cleaning your fire 13 Assembling the fire and laying the coals...

Страница 3: ...ces are installed by a qualified installer in accordance with the current Gas Safety Installation and Use Regulations The installation must comply with these installation instructions and all relevant...

Страница 4: ...r level is not less than 125mm 5 THE CHIMNEY FLUE This appliance can be used with the following types of chimney or flue a A conventional open flue of 7 or above 175mm b A 5 diameter gas flue c A gas...

Страница 5: ...nock out is provided in the rear of the box Having determined the position of the gas pipe the knock out can be removed by a sharp tap with a hammer Provision will have to be made to pass the pipe thr...

Страница 6: ...ch that the holes in the frame and firebox are lined up 2 Screw the frame to the firebox using the 9 self tapping screws supplied 3 Fit the firebox as described on page 5 Laying of ceramics coals See...

Страница 7: ...ls may cause temporary irritation to eyes skin and respiratory tract consequently it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum CAUTI...

Страница 8: ...ls on how to operate each of the appliances can be found as follows Manual Appliances Page 10 Remote Appliances Page 10 Check for spillage 1 Before briefing the customer on how to use the appliance a...

Страница 9: ...best results from your Portway fire we recommend that the fire be serviced In order that the terms and conditions of your warranty are met this must be undertaken annually and the Service Engineer mu...

Страница 10: ...er period 5 Depress the control knob slightly and turn anti clockwise to the MAX position The main burner should now light 6 Turn the control knob anti clockwise to the MIN position The flames will ge...

Страница 11: ...a loud clicking noise will be heard when Control Knob B is turned manually This sound comes from the spring loaded dog clutch between the knob and the motor and can be ignored Extinguishing a Manual...

Страница 12: ...pond to the handset control check that the red LED on the handset lights whilst pressing either of the two buttons If the LED does not light the battery in the handset requires renewing To change the...

Страница 13: ...n to eyes skin and respiratory tract consequently it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum The appliance should be serviced annu...

Страница 14: ...REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS AND TEST FOR SPILLAGE 9 The service record sheet is enclosed with these instructions and should be completed to maintain the validity...

Страница 15: ...3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by CORGI No Service Date Signed Com...

Страница 16: ...e accompanied by evidence of the date of purchase such as a Sales receipt showing that the appliance was bought within 12 months prior to the date of claim 2 The appliance was correctly installed and...