background image

FERRULE

COAXIAL
CABLE

CONNECTOR
ASSEMBLY

10: 

Insert the coaxial cable into the coaxial connector until the wires of the center conductor are visible through the M3 set 

      screw hole.

NOTE: 

Ensure that the split in the ferrule is aligned 90° from the M4 set screw (see inset).

I

COAXIAL
CABLE

10

CONNECTOR
ASSEMBLY

2MM ALLEN
WRENCH

12

CONNECTOR
ASSEMBLY

COAXIAL
CABLE

M4 SET
SCREW

11: 

Use the provided 1.5mm Allen wrench to replace and 

      securely tighten the M3 set screw.

1.5MM ALLEN
WRENCH

11

CONNECTOR
ASSEMBLY

COAXIAL
CABLE

M3 SET
SCREW

J

12: 

Use the provided 2mm Allen wrench to securely tighten the 

      M4 set screw until it squeezes the wire ferrule tightly to the 
      coaxial cable.

K

10

13: 

Replace the coaxial connector cover and tighten into 

      place.

L

13

COAXIAL
CONNECTOR
COVER

COAXIAL
CABLE

M

14: 

Connect the red wire of the coaxial connector to the 

      +24VDC power supply wire with a wire nut.

15:

 Connect the black wire of the coaxial connector to the 

      -24VDC power supply wire with a wire nut.

16:

 Place all connections inside the junction box.

COAXIAL
CONNECTOR

15

14

16

JUNCTION
BOX

3

WIRE NUT

WIRE NUT

Отзывы: