WATER TANK
DEFROST FUNCTION
8
.
MAINTENANCE & CLEANING
Always turn off the device and disconnect the cable before performing maintenance
procedures. All service procedures below are to be performed with the unit in the socket.
Perform before each use or as required.
Check the electrical system
Check the electrical cable for damage at regular intervals.
Keep dust away from surfaces and areas when dry
.
When the water tank is full, the water tank light goes on red and alarm goes on
after 5
seconds. Buzzer beeps 15 times and the compressor and fan shut off. After the water
tank is emptied, the machine will automatically switch to the previous mode while the
compressor will be in 3 minutes of self-protect. Alarm will stop in 3 seconds after the
water tank was emptied and put back, fan starts, and compressor will start in 3 minutes.
1.
The compressor and fan will shut off when the environmental temperature goes
below 5
℃
or above 38
℃
.
2.
Defrost requirement: Compressor running for 30 minutes, temperature sensor
sense the temperature -1
℃
, (last for 10 seconds), compressor stops, defrost starts,
fan continues, defrost light turns on, when the pipe temperature goes to 5
℃
or the
defrost last for 15 minutes, defrost stops.
Note: During defrost, light won
’
t be off until the defrosting is over.
Protection from dust
A
ir filter maintenance
You should frequently maintain the air filter
every 5 days.
Open the top front cover by
pulling it upwards. Pull the filter upwards.