background image

SAFETY NOTES

02

03

PureAiro 

WMDH 33

The WMDH 33 Dehumidifier must always be connected using a grounded electrical 
connection as required for all electrical appliances. The warranty is voided and all 
responsibility for the operation is born by the owner if non-grounded wiring is utilized.

The WMDH 33 Dehumidifier must only be installed, maintained and serviced by a qualified 
technician.

Follow all state and local plumbing and electric codes.

The WMDH 33 Dehumidifier is intended only for operation when the unit is wall mounted 
or in wall and level. Any other orientation could cause water to contact electrical 
components.

If any water may have spread throughout the unit, the unit should be opened and allowed 
to dry thoroughly before reconnecting to electric and restarting.

For proper operation, no obstruction should be located within 914mm of the discharge of 
the unit

Do not insert any objects or fingers into the inlet or discharge. If service is required, call a 
qualified technician. All work on unit should be done with the unit “off” and unplugged or 
the breaker turned “off.”

Do not use water to clean the unit exterior. Only use a damp cloth to clean the exterior and 
always unplug or disconnect the power of unit first.

The drain hose must be installed to ensure the proper flow of condensate water to a drain 
source.

ELECTRICAL SUPPLY

POWER SUPPLY

OUTLET REQUIREMENT

CIRCUIT PROTECTOR

220 Volts AC may cause serious injury from electric shock.

WARNING

TO ENSURE SAFETY:

Disconnect electrical power before servicing.
Only plug unit into grounded electrical circuit.
Do not use extension cord.
Do not use a plug adapter.

220 V, 50 Hz AC, Single Phase

3-Prong

15 Amp Time Delay Fuse or Circuit Breaker

1

2

3

4

DEHUMIDIFIER DIAGRAM

FRONT VIEW

BACK VIEW

AIR  DISCHARGE

FILTER  MAINTENANCE 

REMINDER

FRONT COVER SCREWS 

AND CAPS

AIR INTAKE

FRONT COVER

WALL SCREW HOLES

REAR TOP COVER

Wall screw holes

Back cover

Power Cord 

Routing Options

Drain Line 

Routing Options

Chassis

Содержание WMDH 33

Страница 1: ...et of 220V or hardwired into an existing supply Engineered to drain into a plumbing line or a hub drain Features an internal digital dehumidistat Installation Operations Manual PUREAIRO WMDH 33 PureAi...

Страница 2: ...ul humidity control strategy will lower relative humidity levels below 60 to proactively prevent mold growth The most e ective and e cient way to improve Indoor Air Quality IAQ and prevent mold growth...

Страница 3: ...t Do not insert any objects or ngers into the inlet or discharge If service is required call a quali ed technician All work on unit should be done with the unit o and unplugged or the breaker turned o...

Страница 4: ...e in constant on mode while the dehumidi er is on mode Press the on o button again and a single beep will indicate that the unit is turning o No room conditioning will occur until the unit is turned o...

Страница 5: ...NSTALLATION Dehumidi er not designed for corrosive environment WARNING Step 1 Cutting the two zip ties remove the three screws from the shipping bracket then remove the shipping bracket Fastening of m...

Страница 6: ...ing a square or ruler score the lines and cut with a drywall saw Depending on the installation both walls may need to be cut through SHUT OFF BREAKER POWER BEFORE BEGINNING INSTALLATION WARNING Step 8...

Страница 7: ...um drywall sheathing For alternate installations maintain 1 2 13mm clearance to back of the wall of the dehumidi er cabinet Step 12 Turn breaker power back on Step 13 Set the digital controller to des...

Страница 8: ...y drawing moist air in through the bottom portion of the di user and returning dried air to space out the top portion of the di user Note Avoid blocking the return and supply air ow to maximize unit p...

Страница 9: ...shall constitute the total liability of seller in the case of defective performance of all or any of the equipment or services provided to Buyer Buyer agrees to accept and hereby accepts the foregoin...

Отзывы: