04
05
INSTRUCTIONS
1
SETUP
THE CONTROL PANEL
Variable Speed Control
Place the Sentinel HEPA Pro so that it is in the upright, vertical position.
Plug the machine into a standard 115 volt outlet. Note: Each unit needs 3 amps to operate.
Power the unit on and adjust the speed by turning the variable speed control. The
maximum speed is 750 CFM and the minimum speed is 350 CFM.
The Sentinel HEPA Pro can be operated in the vertical or horizontal postion, depending
on the exact situation. At this point, adjust the machine to the optimal position.
2
3
4
Auxiliary Outlet
Circuit Breaker Switch
The Circuit Breaker Switch protects the unit if there are more than 12 amps of electricity
passing the circuit. If this occurs, the switch will cut off the power to the unit.
CHANGING TH E FILTERS
Loosen the 4 locks that hold the filter board in place.
Slide out the filter panel board.
Remove the used filters and replace with new filters.
1
1
2
2
3
3
WARNING
APPLICATIONS
Water Damage
Odor Control
Other Uses
In this application, the Sentinel HEPA Pro should be placed in the center of the affected area.
The air scrubber will draw in the air, filter it, then blow out the newly cleaned air. To begin the
process,simply turn on the scrubber and it will start cleaning the air. Keep in mind that if you
are working in a large area or one divided by walls, you may need several air scrubbers to
effectively clean the air.
The Sentinel HEPA Pro, when used with the optional activated carbon filter (P/N:), is
excellent at odor control, as well. Simply place the carbon filter in the pre-filter slot and it will
capture a wide variety of odor-causing gas molecules, such as volatile organic compounds
(VOC's), smoke,soot, and paint fumes.
The Sentinel HEPA Pro is also useful in many other applications including mold remediation,
fire damage, dust control, and sewage remediation.
WARNING!
Breathing Hazard
1
2
Tipping Hazard
Use caution when stacking units,
Do not stack more than 2 units on top of each other.
Falling equipment could cause bodily harm.
1
2
3
PureAiro
Sentinel HEPA Pro
Used to time the running time of the device. Start timing when the device is running, and
pause timing when the device is stopped.
Variable
Speed Control
Auxiliary
Outlet
Change
HEPA Filter
Hour Meter
Circuit
Breaker Switch
The Variable Speed Control is used to adjust the power of the machine. Turn the knob in a
clockwise dlirection, to increase the speed from maximum to minimum .The minimum speed
setting is located immediately under the OFF button.
If more air filtration is necessary for a space, you can“daisy chain" or link up to 3 Sentinel
HEPA Pro's to the same outlet. There is a maximum amperage of 12 when the units are
turned off, a maxium of 9 amps when the units are turned on. Other equipment can be
plugged into the same outlet as the Sentinel HEPA Pro as long as it doesn't go above
the max amperage.
Timer
Always wear approved protective gear when changing the filters.
Filters should be changed after each remediation job.
If the indicator light is on, always change the HEPA/Activated Carbon Filter.
When using the Sentinel HEPA Pro in a containment area, always turn off power to open
combustion appliances, such as firelaces, furnaces, water heaters, and HVAC systems, to
avoid the risk of backdrafting carbon monoxide fumes.
If the Filter Change Light iluminates during the remediation process, immediately change
the HEPA/Activated Carbon Filter.