08
09
PureAiro
Daul X
4.8
Press the “Set button” to adjust the set point RH% in 5% increments ranging from 25 to
80% RH. and then.
loop back
to CO. Adjust to CO mode, dehumidifier always running. Press the “MENU
button” to confirm selection and advance to the next screen.
4.9
The display prompts the user that the defrost cycle is in progress.
The defrosting status is displayed on the main interface as a flashing icon until the
defrosting ends and the defrosting lamp disappears. In the meantime, please wait
patiently for the machine to finish frosting.
5.1
The compressor is in a protective condition. During this period, please be patient and
wait for the countdown to end. The dehumidifier will automatically turn on after the
countdown.
5.2
When the purge button is pressed the display will tell the user on the dashboard that
the pump is draining and display a 30-second countdown timer. Until the machine
finishes draining, the display will also prompt the user on the dashboard that the
machine is draining automatically, and display a 30-second countdown.
If the machine has an error and needs service, the onboard control system will display a
diagnostic code. If E1, E4, HI or LO is displayed on the vehicle control screen, please refer
to the following:
1
Solution: Verify that the pump is properly
installed and functioning. If so, unplug the
unit for two minutes, then restart.
LO:
Room Temperature is below 35.6
℉
E1:
Humidity Sensor or Communication
Error
Solution: Check to ensure that the sensor
wire is connected at both ends, if no issues
are visible, the sensor may be faulty.
E4:
Problem with Pump
Solution: Contact us for Assistance.
Solution: Increase the room temperature so
it is within operation range (above 35.6
℉
). If error is still displayed, check the sensor.
Solution: Decrease the room temperature so it is within operating range (below 105
℉
).
If error is still displayed, check the sensor.
HI:
Room Temperature is above 105
℉
E5:
Refrigerant Leak
2
3
4
5
TROUBLESHOOTING