Pure n Natural Systems LA-1000-FM Скачать руководство пользователя страница 5

Adjustable Exhaust Grille 

Large adjustable exhaust grille with individu-ally adjustable vanes 
allows a variable airflow to be presented to the room according to 
size and traffic pattern. 

Safety Interlock System 

Located in the channel behind the collecting cell, the micro-
switch controlled interlock system will not allow operation of the 
LAF

M

 without having the intake panel locked into place. 

Two-Speed Fan Switch 

Your LAF

M

 is equipped with a three-position switch that allows 

for 

High

 and 

Low

 fan speed as well as a center 

off

 position.  The 

electronic collection system and the fans are designed to run 
simultaneously. 

System Light 

The LAF

M

 is fitted with a system light which indicates 

when your air cleaner is in operation.  Located below the 
three-position switch, the light will be lit when all 
system connections are activated. 

Piggyback Fuse System 

The unit is provided with a fused circuit that protects 
valuable components in case of a power surge.  An 
additional “piggyback” fuse is located in the fuse holder  
for easy access if it is needed. 

HOW YOUR MODEL LAF

M

 WORKS 

In business establishments or public buildings, millions of airborne particles are continually being circulated in the air you breathe.  
Your  LAF

M

  Self  Contained  Flush  Mounted  Electronic  Air  Cleaner  removes  the  smoke,  dust,  dirt,  pollen,  and  other  pollutants 

from the air with an electrostatic process which works this way: 

1.

The internal circulating blower mechanism

 

draws the dirt laden

 

air into the system where

 

it first encounters the outer PREFILTER

 

SCREEN.

2.

The PREFILTER SCREEN collects the

 

larger particles from the

 

air and holds them on

 

its intermeshed surface.

3.

In electronic units, the air then passes into

 

the ELECTRONIC

 

FILTER CELL where it

 

first meets the IONIZING SECTION with

 

its

 

many fine ion wires.  These wires charge the

 

airborne particles

 

by 

exciting them with a high

 

electrical charge.  As the charged

 

particles

 

move along to the COLLECTING SECTION,

 

they are

 

trapped by 

the collector plates much

 

like a magnet attracts and

 

collects metal fil-

ings.

4.

In HEPA LAF

M

 units, the air is drawn

 

through a high

 

efficiency, 

hospital grade media pad.  The harmful particles are trapped and

 

held by the closely spaced fibers. 

5.

The ACTIVATED CARBON AFTER-FILTER, the final filter in the

system,

 

removes odors and freshens the air.

6.

The cleaned and purified air is then

 

returned to the room environment.

Activated Carbon 

Afterfilter 

Electronic 
Filter Cell or 
HEPA Media 
Pad Filter Cell 

Prefilter 
Screen 

Dirt Laden Air 

Clean Fresh Air 

L A - F M   I N S T A L L A T I O N   M A N U A L   &   U S E R   G U I D E 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Содержание LA-1000-FM

Страница 1: ...ount Media Air Cleaner Distributed by Pure n Natural Systems Inc purennatural com 1 800 237 9199 COMMERCIAL AIR CLEANER INSTALLATION MANUAL AND USER GUIDE L A F M I N S T A L L A T I O N M A N U A L U...

Страница 2: ...M General Information 8 Application 8 8 Sizing Maintenance 9 9 9 Washing the Electric Cells and Prefilter Replacing the HEPA Media Pad Service 9 Troubleshooting Guide and Chart Diagnostic Checks Power...

Страница 3: ...exhausting of polluted air to the outside is the most common solution to the removal of concentrations of polluted air In doing so however you must also bring supplies of fresh air to take the place...

Страница 4: ...ust Grille Mounting System Two speed Blower Switch System Light Piggyback Fuse System Power Supply Module Not used with HEPA Units Blower Motors COMPONENTS OF THE LAFM AND HEPA LAFM 4 Hood Assembly Th...

Страница 5: ...LAFM Self Contained Flush Mounted Electronic Air Cleaner removes the smoke dust dirt pollen and other pollutants from the air with an electrostatic process which works this way 1 The internal circula...

Страница 6: ...the cell 3 After removing the items in the previous step close and lock the hinged intake panel Preparation for Mounting The LAFM and HEPA LAFM are designed to fit into a T bar drop ceiling Remove as...

Страница 7: ...cal authority Reassembly of the Unit 1 With the unit now in place loosen the 1 4 turn screws on the intake grille and allow the hinged portion to drop down 2 Replace the prefilter screen electronic ce...

Страница 8: ...de air quality How fast is the level of contamination rising What kind of air speed is anticipated ASHRAE Standard 62 81 recommends several different air change formulas depending on the type of estab...

Страница 9: ...ir cleaners and their components are susceptible to damage Take care when working with them to avoid equipment damage Replacing the HEPA Media Pad The HEPA Media pad cannot be cleaned and MUST BE REPL...

Страница 10: ...ping sound and arcing should occur if the cell is properly energized b If no arcing is heard check for continuity through the collector cell then check for failure of the cell due to broken wires crac...

Страница 11: ...ty component or connection in the power supply of your LAFM CAUTION EXPOSURE TO LINE VOLTAGE IN THIS PROCEDURE WARRANTS SPE CIAL CARE BE SURE THE POWER IS TURNED OFF BEFORE CONNECTING OR DIS CONNECTIN...

Страница 12: ...nsure that any malfunction in the electronic air cleaner is quickly and properly repaired Refer first to flow chart below for an outline of the procedure and then refer to the Troubleshooting Guide 12...

Страница 13: ...E FROM POWER SUPPLY IN LAFM BROWN OR WHITE WIRE FROM POWER SUPPLY IN LAFM GREEN GROUND WIRE FROM POWER SUPPLY IN LAFM NEUTRAL CONDUCTOR WIRE GREEN GROUND WIRE L A F M I N S T A L L A T I O N M A N U A...

Страница 14: ...RLOCK MICRO SWITCH 497576 497567 ON OFF SWITCH 497612 497612 MOTOR BLOWER 497602 497609 FUSE 497547 497547 INDICATOR LAMP 497570 497592 POWER SUPPLY 10079 10179 L A F M I N S T A L L A T I O N M A N U...

Страница 15: ...Electronic Filter Cell HEPA Media pad with integrated carbon filter 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Other parts in the LAFM assembly can be obtained by calling our Customer Service Department MODEL LAFM P...

Страница 16: ...ny part thereof which has not been operated in accordance with the operating instruc tions herein contained where components or other accessories not compatible with the LakeAir Electronic Air Cleaner...

Отзывы: