Pure n Natural Systems LA-1000-FM Скачать руководство пользователя страница 15

Part #

Quantity Used 

  #1

  #10179 

  #10107 
  #10130 
  #30007 
  #495169 
  #40137 
  #480029 
  #490128 
  #497567 
  #497602 
  #497609 
  #497612 
  #497547 
  #499072 
  #499081 

(contains 497606 Transformer & 497524 Voltage Quad) Complete Power 
Supply 230V (Electronic Only)  
(contains 497607 Transformer & 497524 Voltage Quad) Complete 
Electronic Filter Cell (Electronic Only)
Ionizer Wire Kit (Electronic Only) - 6 each 
LAFC Hood Assembly 
Instrument Panel 
Ceramic Stand-off Kit (Electronic Only)  
Electrical Schematic Label 
Prefilter Screen 
Safety Interlock Micro-switch 
Motor/Blower 120V(2-HEPA) 
Motor/Blower  230V 
Off/On Rocker Switch 
Fuses 
Carbon Afterfilter (for use with Electronic Filter Cell)
HEPA Media pad with integrated carbon filter 














  Other parts in the LAF

M

 assembly can be obtained by calling 

our 

Customer Service Department. 

MODEL LAF

M

 PARTS SCHEMATIC 

HEPA Filter 

- #499081

(HEPA Unit)

Pre-Filter Screen

 - 

#490128 

Intake Grill

 - 

#20055 

Safety Interlock Micro Switch

 - 

#497567 

Instrument Panel

 - 

#495169 

Description 

 

0079 Complete Power Supply 120v (Electronic Only)  

On/Off Rocker Switch

 - 

#497612 

Power Supply

 - 

#10079 or 10179

Motor Blower

 

 - 

#497602 or 497609

Hood Assembly

 - 

#30007

15 

L A - F M   I N S T A L L A T I O N   M A N U A L   &   U S E R   G U I D E 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Outlet Grill

 - 

#495172

Electronic Cell - #10107 (Electronic Unit)

Ionizer Wire Kit - #10130 (Electronic Unit)

Carbon Post Filter - #499072

Optional SUPER Carbon Post Filter - #499037

Содержание LA-1000-FM

Страница 1: ...ount Media Air Cleaner Distributed by Pure n Natural Systems Inc purennatural com 1 800 237 9199 COMMERCIAL AIR CLEANER INSTALLATION MANUAL AND USER GUIDE L A F M I N S T A L L A T I O N M A N U A L U...

Страница 2: ...M General Information 8 Application 8 8 Sizing Maintenance 9 9 9 Washing the Electric Cells and Prefilter Replacing the HEPA Media Pad Service 9 Troubleshooting Guide and Chart Diagnostic Checks Power...

Страница 3: ...exhausting of polluted air to the outside is the most common solution to the removal of concentrations of polluted air In doing so however you must also bring supplies of fresh air to take the place...

Страница 4: ...ust Grille Mounting System Two speed Blower Switch System Light Piggyback Fuse System Power Supply Module Not used with HEPA Units Blower Motors COMPONENTS OF THE LAFM AND HEPA LAFM 4 Hood Assembly Th...

Страница 5: ...LAFM Self Contained Flush Mounted Electronic Air Cleaner removes the smoke dust dirt pollen and other pollutants from the air with an electrostatic process which works this way 1 The internal circula...

Страница 6: ...the cell 3 After removing the items in the previous step close and lock the hinged intake panel Preparation for Mounting The LAFM and HEPA LAFM are designed to fit into a T bar drop ceiling Remove as...

Страница 7: ...cal authority Reassembly of the Unit 1 With the unit now in place loosen the 1 4 turn screws on the intake grille and allow the hinged portion to drop down 2 Replace the prefilter screen electronic ce...

Страница 8: ...de air quality How fast is the level of contamination rising What kind of air speed is anticipated ASHRAE Standard 62 81 recommends several different air change formulas depending on the type of estab...

Страница 9: ...ir cleaners and their components are susceptible to damage Take care when working with them to avoid equipment damage Replacing the HEPA Media Pad The HEPA Media pad cannot be cleaned and MUST BE REPL...

Страница 10: ...ping sound and arcing should occur if the cell is properly energized b If no arcing is heard check for continuity through the collector cell then check for failure of the cell due to broken wires crac...

Страница 11: ...ty component or connection in the power supply of your LAFM CAUTION EXPOSURE TO LINE VOLTAGE IN THIS PROCEDURE WARRANTS SPE CIAL CARE BE SURE THE POWER IS TURNED OFF BEFORE CONNECTING OR DIS CONNECTIN...

Страница 12: ...nsure that any malfunction in the electronic air cleaner is quickly and properly repaired Refer first to flow chart below for an outline of the procedure and then refer to the Troubleshooting Guide 12...

Страница 13: ...E FROM POWER SUPPLY IN LAFM BROWN OR WHITE WIRE FROM POWER SUPPLY IN LAFM GREEN GROUND WIRE FROM POWER SUPPLY IN LAFM NEUTRAL CONDUCTOR WIRE GREEN GROUND WIRE L A F M I N S T A L L A T I O N M A N U A...

Страница 14: ...RLOCK MICRO SWITCH 497576 497567 ON OFF SWITCH 497612 497612 MOTOR BLOWER 497602 497609 FUSE 497547 497547 INDICATOR LAMP 497570 497592 POWER SUPPLY 10079 10179 L A F M I N S T A L L A T I O N M A N U...

Страница 15: ...Electronic Filter Cell HEPA Media pad with integrated carbon filter 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Other parts in the LAFM assembly can be obtained by calling our Customer Service Department MODEL LAFM P...

Страница 16: ...ny part thereof which has not been operated in accordance with the operating instruc tions herein contained where components or other accessories not compatible with the LakeAir Electronic Air Cleaner...

Отзывы: