Pure H2O QUATREAU 553-B Скачать руководство пользователя страница 1

BOILING

CHILLED

SPARKLING

HOT & COLD

Touch

INSTALLATION, 
COMMISSIONING 
AND USER GUIDE

Содержание QUATREAU 553-B

Страница 1: ...BOILING CHILLED SPARKLING HOT COLD Touch INSTALLATION COMMISSIONING AND USER GUIDE...

Страница 2: ...NSTALLING THE C20 CS20 C50 CS50 Chiller or Chiller Carbonator range SYSTEM DETAILS PIPEWORK VENTILTION POWER REQUIREMENTS IMPORTANT INFORMATION SECTION TWO COMMISSIONING COMMISSIONING THE QT553 B COMM...

Страница 3: ...board asthe mains cold water supply Note that this is in addition to the isolated Mains Cold Water that will be used to feed a cold supply to the system 4 Drainage Trapped upstand located back left ha...

Страница 4: ...e of the box to reveal the system so that you don t have to lift it upwards out of the box Carefully place one hand under the front lip of the system next to the filter this will give you a firm hold...

Страница 5: ...ourse dictate whether this is possible Before you start cutting ensure that you have set up a jig or a template device to prevent the drill bit moving when you start the cut Once the hole is prepared...

Страница 6: ...to tighten the bolts you will pull the tap down onto the work surface and create a tight fit Do not over tighten once the tap is firmly in place stop Your tap is now fixed in place 4 Connect two lengt...

Страница 7: ...a length of 1 4 pipe to the pure inlet on the right hand side of the QT553 B Also connect the 1 4 isolation valve just before the inlet This will be sued for control purposes STEP 2 With the QT553 B...

Страница 8: ...chiller performs to its specification Failure to install this will void the warranty on this module The Quatreau chiller carbonator is sited next to the 553 B control unit Usually this will be to the...

Страница 9: ...250 226 140 391 55 107 47 SYSTEM DETAILS QUATREAU TOUCH Note Requires 40mm diameter hole in counter top positioned minimum 50mm back from the edge of the sink INSTALLATION...

Страница 10: ...Mains hot and cold services must have isolators fitted The thermostatic valve should be fixed to the side of the cupboard in which the QT553 B or C20 CS20 C50 CS50 is to be installed Ensure that both...

Страница 11: ...ust vented adequately A vent kit should be purchased with each system Ventilation is cut into the base of cupboard under the chiller and a duct run to the kick board The kickboard is also cut to permi...

Страница 12: ...E 230V 230V 230V WATTAGE Max consumption 2 56KW 130W 296W Standby consumption 80W 130W 100W START UP TIME 10 minutes 10 minutes MAX WORKING PRESSURE 3Bar 3Bar CO2 CAPACITY 100ltrs carbonated water INS...

Страница 13: ...ot elbow inlet on the side of the QT 553B 4 Connect the other braided hose to the cold mains water supply and fit to the cold mains 3 8 inlet elbow on the side of the QT 553B 5 Connect a supply of col...

Страница 14: ...anks are full of water you can add the gas bottle to the front of the QT 553B 2 Power up the chiller carbonator you will hear the fan activate and possibly the pump 3 Run the chilled water function at...

Страница 15: ...pressure requirements to max 3Bar SECTION H Optimum setting for mains Hot Cold water Finally adjust the flow rate of the mains hot and cold down to a point where it doesn t splash when washing hands T...

Страница 16: ...will display boiling and the top left control quadrant cup icon will flash red several times before illuminating red To turn off the boiling water press once any of the four control quadrants QUATREAU...

Страница 17: ...p right control quadrant snowflake icon once When the tap is releasing chilled water the top right snowflake will illuminate white and the central screen will display chilled To turn this function off...

Страница 18: ...ling The sparkling water function will run for 30 seconds earlier models have an 8 second timeout before automatically switching itself off Note If the sparkling water is spluttering or is not carbona...

Страница 19: ...hermostatic valve in a clockwise direction to make the water colder and anti clockwise to make it hotter COLD MAINS COLD WATER To activate touch the bottom left control quadrant sink icon twice To tur...

Страница 20: ...chiller carbonator needs to be sited with adequate ventilation to function correctly QUATREAU CS CHILLER CARBONATOR Models C20 20ltr hr chiller CS20 20ltr hr chiller carbonator C50 50ltr hr chiller C...

Страница 21: ...ator by a half turn in a clockwise direction To decrease the level of carbonation turn the regulator by a half turn in an anti clockwise direction Between adjustments you must run off several glasses...

Страница 22: ...s supported 4 Rotate the canister in a clockwise direction being careful not to cross thread the regulator 5 Rotate until you hear a hissing sound This is the gas being released from the canister It i...

Страница 23: ...adjust this function The CO2 canister will need replacing please refer to the sparkling water section in the user guide for details The boiling flow can be controlled by the PRV located on the side o...

Страница 24: ...R REQUIREMENTS 1 x 13A socket 2 x 13amp sockets RCD Protected VOLTAGE 230V 230V 230V WATTAGE Max consumption 2 56KW 130W 296W Standby consumption 80W 130W 100W START UP TIME 8 minutes 10 minutes MAX W...

Страница 25: ...INSTALLATION DETAIL BY AUTHORISED PURE H2O TECHNICIAN ONLY INSTALLATION DATE INSTALLATION NOTES CONTACT CUSTOMER SERVICE 01483 617000 customerservice pureh2o co uk USER GUIDE...

Страница 26: ...Boundary Business Centre Boundary Lane Woking Surrey GU21 5DH United Kingdom www quatreau com QT 06 19 Quatreau is a registered trademark of the Pure H2O Company Limited Copyright 2019 The Pure H2O Co...

Отзывы: