SEQUENCE ( II )
- Install Oil Supply
(
Pressure) Line
Typical Oil Supply Line Connection
Install pressure port fittings
Step 1.
Find the oil pressure sending unit or port plug along oil galley on the engine. The oil
pressure sending unit normally has a wire or cable running to the ECU. If you are unable to connect
to the oil pressure sending unit, find another pressurized oil port (usually near the factory full-flow oil
filter) that you can connect to for oil supply.
Note:
It is recommended to put a gage on the
selected port and run the engine at high idle to verify the oil pressure under operation. As
long as the oil pressure is under 65 psi, you can install the standard metering jet. If the
pressure is above 65 psi, please contact Puradyn technical staff for recommendation.
Step 2.
After locating the oil port that you will be connecting to, install the shutoff valve supplied
from the kits bag, and install the fitting to the oil port (also,
a 1/8” street tee and ¼” NPT bushing have
been supplied for different adaptation.
Step 3.
Route the high pressure hose from
Step 2
to the bottom of the unit and connect it to
the supply fitting.
Note: After system installation is complete, remember to open the Shutoff
valve, so the oil can travel from the engine to the pura
DYN
®
System.
2.
Install shutoff valve fitting to oil supply
port.
Connect
high-pressure
hose
(prepared earlier) to this installed shutoff
valve fitting.
1.
Locate oil galley plug, oil
pressure sending unit or other
pressurized oil port or galley.
3
.
Route and connect
high-pressure hose from
Step 2
to supply fitting (or
optional sample valve kit)
on the bottom of the MTS
unit.
Sample Valve kit
Option:
15-00245