16
Remove white protective film from faucet base. Verify faucet body, metal base, and rubber base washer are in place
above sink (Items 1, 3, and 2).
Lower faucet into mounting hole and place faucet over hole.
Install slotted washer, spacer, faucet washer, and nut onto faucet nipple below sink and snug them up
(Items 4, 5, 6, 7 and 8). Be sure to properly align faucet before tightening. Do not over tighten.
Install faucet connector (Item 9), packaged with faucet, onto faucet nipple.
The spacer is typically necessary on stainless steel sinks and thin counter tops. If counter top or sink is too think (5/8” or
thicker) remove the spacer from the installation.
CAUTION!
Plastic Parts will break if screws are over tightened!
Tubing Connections
1. At the bottom of the faucet assembly you will find three tubing connections;
2 are barbed and one is a push in
type fitting.
2. For the Air gap you will use the 2 barb fittings, the smaller fitting is for the 1/4”
tubing and will be connected to the RO system. The larger barb fitting will
use the 3/8” tubing and will be connected to the drain.
NOTE:
If you have difficulty fitting the tubing onto the barbed fittings, try
running hot water over the end of the tubes.
NOTE:
Cut the tubing to be longer than what you will need because you
will be able to trim it after you install the faucet assembly. Prepare
the tubing with a fresh cut and make sure that it is free of dirt and
any foreign materials.
3. Take another length of 3/8” tubing and make sure it is has a fresh cut and is
free of foreign materials and any scratches on the outside surface. Install the
tubing into the push in type fitting at the base of the faucet. Make certain
that it is inserted all the way in; once inserted give it a slight pull to make sure
it is locked into the fitting. You have now completed the tubing connections.
NOTE:
To disconnect tubing from the product water fitting, hold the
collet firmly against fitting body and pull the tube from the fitting.
Repeated assembly and disassembly will cause wear to the inner
body. Visually inspect for excessive wear and replace the inner
body as needed to protect against any leaks.
Cleaning the Faucet
Wipe the faucet with a soft cloth, avoid abrasive cleansers.
Air Gap Faucet Installation
1/4”
Red
Tubing
3/8”
Red
Tubing
Product Line from
RO Manifold
(3/8” Blue Tubing)
Faucet Adapter
O
9