Adjusting High Voltage Output

 

In case of excessive arcing on a clean, dry Cell, there is 

an adjustable resistor mounted on the Power Board. 

 

1.  Turn off the system switch before opening the unit. 

 

2.  Remove  the cover by  slipping  the  "S"  hook  from  the 

chain and letting the cover gently down. 

 

3.  Lift the cover up off the rear hinge. 

 

4.  Remove the power box cover. 

 

5.  With  a  small  slot  screwdriver,  adjust  "R-2"  slightly 

clockwise to reduce voltage to the cell.  Do not reduce 

the  voltage  too  much  or  the  efficiency  of  the  air 

cleaner will be reduced. 

Removing The Power Box

 

1.  Shut off main breaker or switch. 

 

2.  Remove the cover as described previously. 

 

3.  Open power box cover. 

 

4.  Disconnect the following wires: 

 

 

Terminal Block  -Red, blue or yellow, black and 

 

 

 white leads from motor 

 

 

-Supply line leads 

 

  Power Board 

-Orange or grey leads on 

 

 

 

 

 HV1 and HV2 

 

5.  Remove  the  two  nuts  holding  the  power  box  to  the 

cell section. 

 

 

 

TECHNICAL DATA 

 

 

 

TROUBLESHOOTING GUIDE

 

  PROBLEM: 

  CHECK: 

Unit Does Not 

Operate 

1.  Main breaker is 

ON

 or voltage 

is supplied to unit. 

2.  Main supply fuse or breaker is 

not tripped. 

3.  Unit cover is completely closed 

and locked into place. 

4.  Power switch is 

ON

Performance 

Indicator Light Is Not 

Lit 

1.  System switch is 

ON

2.  Remove Cells, close access 

door and turn unit 

ON

.  If 

Performance Indicator is still 

off, problem is in the power 

box.   If light comes on with no 

cells, then there is a short 

circuit in the cells.  Place one 

cell in the unit, close access 

door and turn unit 

ON

.  If the 

light comes on, check the other 

cell by the same method.  

When it has been determined 

which cell is the problem, look 

for bent plates, broken ionizing 

wires or burnt insulators or if 

cell is completely dry after 

washing. 

Performance 

Indicator Light Is Lit, 

Fan Not Working 

1.  Fan control switch is in proper 

position. 

2.  Motor leads are connected to 

terminal block. 

Cells Arcing 

Excessively 

1.  Cells are completely dry after 

washing. 

2.  Cell plates are not bent or 

spaced too close. 

3.  Cell insulators are not cracked, 

broken or burnt. 

4.  Cell is dirty and needs cleaning. 

5.  Broken ionizing wires. 

Dimensions 

Length 

29.5 in 

75.0 cm 

 

Width 

27.0 in 

68.6 cm 

 

Height 

14.5 in 

37.0 cm 

Weight 

 

95.0 lbs 

43.0 kg 

Input Voltage   

120 V  60 Hz 

 

Power 
Consumption 

 
(max) 

350 Watts 

 

Air Flow 

High 

1300 CFM 

2210 m

3

/hr 

 

Medium 

1050 CFM 

1785 m

3

/hr 

 

Low 

 750 CFM 

1275 m

3

/hr 

Motor 

 

   1/12 HP 

 

Table 2 —  Technical Data

 

Fig. 8 —  Dimensions

 

Содержание SSCB15G-R

Страница 1: ...MODELS SSCB15W R SSCB15W RE SSCB15G R SSCB15G RE CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT FOR TECHNICAL SUPPORT AND REPLACEMENT FILTERS CALL 416 410 3...

Страница 2: ...d spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employ...

Страница 3: ...ALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable t...

Страница 4: ...tine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX...

Страница 5: ...cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indi...

Страница 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt...

Страница 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt...

Страница 8: ...Ionizing Wire R8 0443 10 Safety Interlock Switch C5 0202 11 Red Indicator Light C5 0113 12 Power Switch Gray C5 0222 Description Part Number 12a Power Switch Black C5 0221 13 3 Position Slide Switch G...

Страница 9: ...ve parts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are...

Отзывы: