OPERATION & MAINTENANCE 

Wiring 

All  wiring  must  comply  with  applicable  codes  and 

standards.    See  unit  rating  label  for  correct  voltage  and 

amperage. 
1.  A knockout is provided on top of the unit, adjacent to 

the  wiring  compartment.    For  convenience,  a  wall 

switch may be installed near the Air Cleaner, in series 

with the power source, to turn the unit on and off. 

2.  Remove the cover of the wiring compartment to locate 

the  input  leads  and  ground  stud.    The  Air  Cleaner 

must be grounded for proper operation and safety. 

3.  Once the unit is mounted and wired, the cover can be 

replaced on the hinge and the chain replaced on the 

"S" hooks.  Close the cover by sliding it forward, lifting 

the cover over the front flange and sliding it back into 

place. 

Operation Check

 

1.  With  the  cover  closed  and  in  place,  turn  the  system 

switch on. 

2.  Adjust the fan speed with the slide switch.  Insure the 

unit functions on all speeds. 

3.  The  Performance  Indicator  Light  should  be  lit,  which 

indicates the Power Board is functioning properly. 

When  the  Air  Cleaner  is  new  it  may  arc  or  periodically 

make "snapping sounds".  A slight  odor of ozone may be 

noticeable.  The arcing and odor are due to rough edges 

and  burrs  on  the  cells.    These  symptoms  will  disappear 

during the first few weeks of normal operation.  The ozone 

levels are well below government standards for indoor air 

concentration. 

Maintenance Schedule 

The Collecting Cells and Prefilters must be cleaned on a 

regular basis for the unit to function at its peak efficiency.  

The frequency of cleaning will vary from one environment 

to another.  The following is an average wash cycle: 

 

Stores,  Offices,  Computer  &  Conference  Rooms  = 

4 Weeks 

 

Cafeterias, Restaurants, Lounges = 3-4 Weeks 

 

Bars, Bingo halls = 1-3 Weeks 

Cleaning & Service 

1.  Turn  off  the  system  switch  and  wait  15  seconds  for 

high voltage to dissipate. 

2.  Open  the  cover  and  cell  access  door  and  remove 

collecting cells  and prefilters.  

Cell  plates  are  sharp.  

Handle with care.

 

3.  Place  Cells  in  tub  and  spray  completely  with 

DAX 

Detergent

,  allowing  detergent  to  run  down  both 

sides  of  plates  and  ionizing  wires.    Let  sit  for  5 

minutes.    Rinse  Cells  well  with  hot  water  (140ºF  / 

60ºC maximum).  Repeat washing process 3 times. 

4.  If  dirt  or nicotine  remains  on  plates,  let  Cells soak  in 

hot  soapy  water  for  30  minutes.   

Never  use  any 

instrument  to  clean  the  cell,  as  this  may  damage 

the ionizing wires or bend cell plates. 

5.  Spray Prefilters with 

DAX Detergent

 and rinse well. 

6.  To dry cells, tilt on 45º angle against wall with arrows 

pointing sideways.  Allow to dry completely for 10-24 

hours. Place in sunlight for faster drying time. 

7.  When  the  Cells  and  Prefilters  are  dry,  place  them 

back  into  the  unit.    The  arrow  on  the  cell  points  up.  

The red fiberboard on the Cell should line up with the 

contacts in the cabinet.  Close door and cover.  If the 

Cells  arc  when  the  switch  is  turned  on  or  if  the 

Performance  Indicator  Light  does  not  come  on,  then 

the Cells are still wet.  Allow more time for drying. 

The use of  

DAX  Detergent

 is strongly recommended for 

cleaning as it is a heavy-duty solution used expressly for 

removal of accumulated pollutants on Cell plates.  If used 

as  directed, 

DAX

  will  not  harm  aluminum  or  steel.    Any 

problem  arising  out  of  the  use  of  another  cleaning  agent 

will  void  the  warranty.    Do  not  use  detergents  that  are 

corrosive or abrasive or detergents containing chlorine or 

ammonia. 

 

DAX  Detergent 

is available in 1 gallon (4.54L) and 4.8 

gallon (22L) containers as well as 45 gallon drums (204L). 

Service Maintenance

 

1.  Determine if the Air Cleaner is performing properly by 

seeing that: 

 

System switch is 

ON

 

 

Performance indicator is 

ON

 

 

2.  A  simple  test  to  check  hi-voltage  would  be  to  blow 

dust  or  cigarette  ash  into  the  intake  grill.  An  audible 

arc  or  snapping  sound  should  be  heard,  ensuring 

good hi-voltage. 

 

3.  If  in  doubt,  and  if  the  Cells  are  not  collecting  any 

carbon  or  nicotine  tars,  then  see  "Troubleshooting 

Guide" or consult your installation dealer. 

WARNING 

Electrical shock can cause injury or death. Be certain 

main line disconnect switch is off before wiring.  

CAUTION 

Make  sure  Air  Cleaner  switch  is 

OFF 

before 

performing  any  maintenance  or  removing  any 

components.  

CAUTION  

Damage  to  Cells  may  occur  if  improperly  handled  or 

washed.  Do  not  wash  Cells  in  a  dishwasher.  Never 

use  any  object  to  clean  between  the  cell  plates,  as 

this  may  cause  damage  to  plates  or  ionizing  wires. 

Never place cell in oven to dry. The edges of the cell 

may be sharp - handle with care.  

WARNING 

Electronic  Air  Cleaners  use  high  voltage  (low 

amperage).  Only  trained  personnel  should  perform 

service.  Use caution.  Electric shock can cause injury 

or death.  

Содержание SSCB15G-R

Страница 1: ...MODELS SSCB15W R SSCB15W RE SSCB15G R SSCB15G RE CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT FOR TECHNICAL SUPPORT AND REPLACEMENT FILTERS CALL 416 410 3...

Страница 2: ...d spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employ...

Страница 3: ...ALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable t...

Страница 4: ...tine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX...

Страница 5: ...cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indi...

Страница 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt...

Страница 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt...

Страница 8: ...Ionizing Wire R8 0443 10 Safety Interlock Switch C5 0202 11 Red Indicator Light C5 0113 12 Power Switch Gray C5 0222 Description Part Number 12a Power Switch Black C5 0221 13 3 Position Slide Switch G...

Страница 9: ...ve parts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are...

Отзывы: