MAINTENANCE

The power unit should be checked frequently for debris and/or build up on the cooling fans which may interfere with proper flow to 
cool the unit during operation. The cooling fans should be cleaned with a vacuum to remove any buildup at least every 3 months or 
more frequently if the unit is mounted in an area where excess dust or debris my be present. 

Deep Cycle Batteries generally last between 3 to 5 years in a sump pump backup installation. It is recommended that the battery is 
tested every 6 months to ensure it is ready for service.

FOR YOUR  RECORDS

Date of Purchase 

Place of Purchase 

Serial Number

ATT

ACH RECEIPT HERE

Installed by:

Model Number

Note:
You 

MUST retain your original purchase receipt along with this manual. 

In the event that you need to exercise a warranty claim, you 

MUST send 

a copy of the purchase receipt along with the material or correspondence. 
Please email [email protected] for return authorization and instructions.

Содержание BU-1500

Страница 1: ...e provide this manual to the property owner responsible for the service and maintenance of the sump pump system 2723 Kersten Court Kalamazoo Michigan 49048 www PumpSpy com INSTALLATION AND SERVICE MANUAL BU 1500 PRIMARY SUMP PUMP BATTERY BACKUP POWER SYSTEM ...

Страница 2: ... and well ventilated Avoid installing in direct sunlight DO NOT bypass grounding wires or remove the ground prong from the plug DO NOT use an extension cord NEVER plug this unit into an outlet while standing on a wet surface NEVER lift this product by the electrical power cord NEVER attempt to open or service this unit while it is connected to an electrical power supply DO NOT pump gasoline or any...

Страница 3: ... the deep cycle battery The Charging Indicator will be RED while charging the battery and GREEN once the battery is fully charged When you loose household power the Power Unit will automatically activate and convert your 12VDC Battery to 120VAC Pure Sine Wave output at both of the Power Unit Outlets It is recommended that you keep both the Charger Switch and the Power Switch in the ON position unl...

Страница 4: ...acturer s recommendation 6 Plug the power unit into the 120VAC outlet 7 Confirm that the Charger Switch and Power Switch are in the OFF Position Plug your sump pump into either of the two 120VAC Output Power Outlets 8 Turn on both the Charger Switch and the Power Switch The Power Indicator LED should be green Your charging indicator LED will be red if your battery is charging or green if fully cha...

Страница 5: ...et and impeller area PUMP RUNS AND REMOVES WATER BUT DOES NOT SHUT OFF 1 Float is stuck in the on position Check to make sure the float is free to move up and down without obstruction 2 Switch may be defective Consult factory PUMP RUNS BUT DELIVERSVERY LITTLE WATER 1 Vertical lift is approaching the pump s maximum lift capability Refer to the above maximum lift chart 2 Pump s inlet is partially bl...

Страница 6: ...atteries generally last between 3 to 5 years in a sump pump backup installation It is recommended that the battery is tested every 6 months to ensure it is ready for service FORYOUR RECORDS Date of Purchase Place of Purchase Serial Number ATTACH RECEIPT HERE Installed by Model Number Note You MUST retain your original purchase receipt along with this manual In the event that you need to exercise a...

Страница 7: ...for warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANTTERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Michigan The warranty period will not be extend...

Отзывы: