OPERATION
CHARGER SWITCH
POWER SWITCH
CHARGING
INDICATOR
POWER
INDICATOR
REVERSE POLARITY
PROTECTION
OUTPUT POWER
OUTLETS
COOLING FANS
POSITIVE
BATTERY
TERMINAL
(RED)
NEGATIVE
BATTERY
TERMINAL
(BLACK)
When 120VAC household power is available to the Power Unit and the unit is powered ON (Power Indicator
is “GREEN”) , household power is directly routed through to both of the Output Power Outlets on this unit.
While the CHARGER SWITCH is in the on position, the Power Unit is also charging the deep cycle battery.
The Charging Indicator will be “RED” while charging the battery and “GREEN” once the battery is fully charged.
When you loose household power, the Power Unit will automatically activate and convert your 12VDC Battery
to 120 VAC Pure Sine Wave output at both of the Power Unit Outlets.
It is recommended that you keep both the Charger Switch and the Power Switch in the “ON“ position unless
you are changing the battery or performing other maintenance on the unit.
The STATUS INDICATOR LED will turn RED when the Power Unit is overloaded, overheating, receiving low
household voltage, or has a short circuit. See Troubleshooting Guide for more information.
STATUS
INDICATOR