Notice:
A part of the inscription of the keypad is exchangeable. Cautiously use
tweezers to find the small gap at the right side of the keypad. Widen the gap a little
and remove the label.
Every unit comes with labels in German, English and French. The unit is supplied
with labels in German. The labels in other languages are in the operating manual.
3.5.2 Key Functions
The MESEP digital is set up by four keys. It is not required to adjust potentiometers.
Therefore, putting the unit into operation is very simple.
The key functions are as follows:
TEST
•
Short manipulation effects metal indication. The separating drum switches brief
into the ejection position. The function serves to test the metal separator by key-
pressing. At the same time, the four LEDs show the currently selected sensitivity
value as a LED combination.
•
Do holding the key. The separating drum switches into the ejection position as
long as the key is being pressed. This enables taking of material samples from
the conveying flow. In this way, discharge of a dosing unit or mixer mounted on
the metal separator can be performed by key pressing.
F1+
Short manipulation shows the currently selected sensitivities for 5 sec. (refer to
sensitivity table, chapter 5.2). Longer pressing of F1+ increases the sensitivity
unless maximum sensitivity was reached.
F2-
Short manipulation shows the currently selected sensitivities for 5 sec. (refer to
sensitivity table, chapter 6.3). Longer pressing of F2- reduces the sensitivity unless
minimum sensitivity was reached.
RESET
This key is used to clear an indicated fault after elimination of its reason.