Model: RM1-15 

Receptacle Module 

Installation Guide and 

Owner’s Manual 

 

 

The Inventors Of: 

 

19201 Parthenia St.  Suite J 

Northridge, CA 91324 

P: 818.701.9831 F: 818.701.1506 

[email protected]  www.pcslighting.com 

 

CONFIGURATION 

Once your RM1 is installed it can be configured either 
manually or with the UPStart Setup Software.  

Refer to one of the Keypad Controller’s Manual 
Configuration Guide available on the PCS website for further 
details on Manual configuration to add your RM1 device into 
a UPB network and link it to various Keypads devices.   

Although the factory default operation of the RM1 is very 
useful in many situations, it is highly recommended that you 
program your RM1 with a Powerline Interface Module (PIM) 
and UPStart Configuration Software to take advantage of its 
many configurable features. User Guides are available on our 
website, if you need further assistance on how to configure 
your system. 

OPERATION 

The Receptacle Module operates according to commands 
sent by one or more UPB controllers. The RM1 can accept 
powerline commands from any UPB-compatible transmitter 
such as PulseWorx Keypad Controllers, Timed Event 
Controllers, Wall Switches, Interface Modules, approved 
Third-Party Controllers and touch screens.  The RM1 can be a 
member of up to 16 scenes with the capability to store a 
pre-set relay state (on, off, or blink) for each scene. 

 

 

 

 

 

 

 

 

 

 

         

Program Button

 

 

 

 

 

 

 

 

         Status LED 

 

 

 

 

 

 

SETUP Mode 

When configuring, it will be necessary to place the RM1 in SETUP 
mode.  To do this, 

press the Program Button, located in the top 

outlet ground hole, five times rapidly

 using a non-metallic 

toothpick.  The Status LED will continuously blink Blue, located in the 
bottom outlet ground hole, when the device is in SETUP mode.  To 
exit SETUP mode, press the Program Button once or wait five minutes 
for it to time out. 

AUTO-OFF Timer 

The programmable Auto-Off Timer has the ability to set a “maximum 
on time” up to 240 minutes.  If the appliance is not turned off, the 
module will implement it automatically. The RM1 can also be 
configured to inform the network when appliance has been turned 
off.  This feature allows the RM1 to remotely control other devices or 
update indicator LEDs on Keypads. 

 T

EST Mode 

A manual test feature allows the device to be turned ON and OFF 
locally.  To enable the TEST mode

 press and hold the Program Button 

on the RM1 for three seconds

.  The Status LED will blink Magenta to 

indicate TEST mode.  The appliance can now be turned ON and OFF by 
single-tapping the Program Button.  Press and hold the Program 
Button again for three seconds to exit from TEST mode. 

Factory Default Settings 

To restore the following default settings put the RM1 into SETUP 
mode and 

then press the Program Button ten times rapidly

.  The 

Status LED will blink red to indicate that factory defaults have been 
restored.  Press the Program Button twice more to stop the blinking. 

Network ID:

 

255 

Unit ID:

 

58 

Network Password:

 

1234 

Receive Components:

  Scene #1 = ON @ Snap 

 

Scene #2 = OFF@ Snap 

 

Scene #8 = Blink @ 0.5 secs 

TYPICAL USES 

The RM1 is perfect for controlling120VAC non-dimming loads such as:  

 

Pumps, Fans 

 

Low voltage landscape transformers,  

 

Coffee makers,  

 

Christmas lights 

LIMITED WARRANTY 

Seller warrants this product, if used in accordance with all applicable 
instructions, to be free from original defects in materials and 
workmanship for a period of five years from the date of purchase.  
Refer to the warranty information on the PCS website 
(www.pcslighting.com) for exact details. 