background image

 

Model: RM1-15 

Receptacle Module 

Installation Guide and 

Owner’s Manual 

 

 

The Inventors Of: 

 

19201 Parthenia St.  Suite J 

Northridge, CA 91324 

P: 818.701.9831 F: 818.701.1506 

[email protected]  www.pcslighting.com 

 

 

 

 

 

 

 

 

FUNCTION 

The RM1 is ideal for remotely controlling one or more 
120VAC non-dimming appliances with a maximum rating of 
15 Amps. The RM1 will replace any standard wall outlet, the 
top outlet is controlled.  No additional wiring is required.  Its 
lower outlet allows vacuums, computers, and other devices 
that do not require remote control to be plugged in to the 
normal electrical circuit.  
 
UPB controllers and modules can be freely located anywhere 
throughout the home.  No additional wiring is required and 
no radio frequency signals are used for communication. 

IMPORTANT SAFETY INSTRUCTIONS 

When using electrical products, basic safety precautions 
should always be followed, including the following: 

 
1.

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 

2.

 

Keep away from water.  If the product comes in contact 
with water or other liquid, turn off the circuit breaker 
and unplug the product immediately. 

3.

 

Never use products that have been dropped or damaged. 

4.

 

Do not use this product outdoors. 

5.

 

Do not use this product for other than its intended 
purpose. 

6.

 

Do not connect multiple lamps or appliances that, when 
combined, exceed the maximum load ratings of the 
product. 

7.

 

To avoid any risk of fire, burns, personal injury or electric 
shock, install this product out of the reach of small 
children. 

8.

 

Do not cover this product with any material when in 
use. 

9.

 

This product uses grounded plugs and sockets to reduce 
the risk of electric shock.  These plugs and sockets fit 
only one way.  If they do not fit, consult an electrician. 

10.

 

SAVE THESE INSTRUCTIONS. 

 

INSTALLATION 

The Receptacle Module is designed for indoor use with devices that 
plug into a grounded power outlet.  To install the RM1 module: 

1.

 

Disable circuit supplying power to outlet at the circuit breaker or 
fuse panel.  

2.

 

Remove the existing wall plate and outlet 

3.

 

Label wires connected to existing device. 

4.

 

Disconnect existing device.  

5.

 

Strip wires have a length of ½” of bare wire. 

6.

 

Install device per wiring diagram below. 

7.

 

Torque terminal screws to 12-14 inch-pounds 

8.

 

Mount the receptacle in to the wall box.  

9.

 

Attach wall plate, and then restore power to the circuit. 

10.

 

Plug the controlled device into the top socket on receptacle 
module.  The appliance/device current rating must not exceed 15 
Amps. 

11.

 

Turn the device’s power switch to its ON position. 

If desired, another device can be plugged into the bottom outlet of 
the receptacle module, which is always powered. 
 

CAUTION

: Do not insert metal objects into the module while it is 

connected to power. 
  
 
 
 