12
ConveyMerge Guide
Publication ERSC-1020 Rev 1.1 – April 2020
The
Left Line
is a separate subnet of
ERSC
modules and its most downstream zone has to physically
discharge on to the
Merging Zone
.
The
Right Line
is a separate subnet of ERSC modules and its most downstream zone has to physically
discharge on to the
Merging Zone
.
All three subnets must be connected to a common Ethernet switch only after each subnet has been Auto-
Configured.
S
ENSOR
P
LACEMENT
It is very important for the internal
ConveyMerge
logic, that the product
is seen by only one photo-eye at a time.
S
TANDARD
M
ERGE
S
ENSOR
P
LACEMENT
Figure 3 shows a suggested sensor arrangement for Standard Left Line and Right Line arrangement to flow into the
Merging Zone
.
FIGURE 3 - SENSOR PLACEMENT FOR STANDARD MERGE