background image

3/4 CHANNEL SWITCH -

  When the 3 channel chase patterns are

selected, channels 1 and 4 are the same,  this enables either channel
to be used as one of the 3 chase channels.

FRONT PANEL

LEDs

 (Light Emitting Diodes)

 -

 one LED for 

Standby/Go

indication, one LED for Mains (

Power

) indication plus one 

Monitor

LED per channel.

STANDBY SWITCH -

 In

 

Standby

  the Monitor LEDs stay working

so a particular function may be selected before enabling the lights by
switching to 

Go

.  

Standby

 may be overrriden by e.g. a Pulsar Litefoot

connected to the channel 6 input of the 

Remote Control Socket

 on

the rear of the unit.

MASTER DIMMER -

 The overall brightness level of all the channels

is controlled by the

 Master Dimmer.

MANUAL BUTTONS  -

 The Manual buttons will flash a channel to

the

 Master Dimmer 

level at any time, providing the unit is 

NOT

 in

Standby.

CHANNEL SELECTION SWITCHES - 

Each Channel can be

individually switched to select a feature.

The

 Off, Half 

and 

Full

 functions statically control the output brightness

of the desired channel.

The

 Chase 

function steps a choice of light patterns in a forward or

reverse direction through a 4 channel display at variable 

Speed

,

continuously or for the duration of each bass beat of an audio signal.
The 

Slope 

control will vary the chase from a crossfade to a switching

chase.

For

 Sound-to-Light 

the 

Slope

 control acts as a 

Contrast

 control,

which varies the effect from a gentle fading action through to a fast
switching effect.

The 

Sound-to-Light

 function separates an audio signal into 4 audio

bands and uses the volume in those bands to control the 4 channels.
The Sound to Light feature has fully automatic Sound-to-Light circuits
with a master Automatic Volume Control (AVC) circuit to adjust for
overall changes in the music volume and one AVC circuit for each
audio channel to adjust for changes in the balance between, for
example, the bass and treble.

The 

Remote

 position enables the unit to become a 4 channel dimmer

pack in 

MODE 1

 (channel 5 lo) controlled from any 0 - 10V desk,  OR

a remotely controlled Chaser/Soundlite in 

MODE 2

 (channel 5 hi)

controlled either from a 0-10V desk or a Pulsar

 Litefoot 

foot switch

PATTERN SELECT SWITCH(ES) -

 Select a particular pattern or

allow the unit to 

AutoChange

 the  pattern  after a number of chase

steps,  Note that the patterns 

 Flip-Flop

 and 

Flash

 are NOT included

in the

 AutoChange

  function and for this reason are printed in grey.

DIRECTION SELECT SWITCH -

  Select

 Forward, Reverse,

Bass Direction Change, Bounce/2, Bounce/4 

or allow the unit to

Autochange

 the direction after a number of chase steps.

CONSTANT SPEED/BASS BURST SWITCH -

 With an Audio

input, 

Bass Burst

 gives a burst of chase steps for the duration of the

bass beat.   The number of chase steps per beat depends upon the
setting of the 

Speed 

control.

CHASE SPEED CONTROL -

 Approx 10 Mins per step at 

Min

, to

approx 50 steps per second at 

Max

.   With 

Bass Burst

 selected, the

number of flashes per bass beat is determined by the setting of the

Speed 

control - from 1 step per beat at 

Min

 to around 20 steps per

beat at 

Max

.

FUSES & PRECAUTIONS

If a channel fails to light, a fuse may have blown.  These fuses will only
blow if the output is overloaded.  Do not exceed the maximum load of 5
Amps per Channel and do not short circuit the outputs.  We
recommend that you check your lighting equipment regularly for
damaged wiring, loose connections and potential short circuits.  If a
fuse blows, locate and rectify the fault before replacing it.

One, 5 Amp, F-Fast, 5 x 20mm, Ceramic, High Rupture Current
(HRC) output fuse is provided for each channel. Only this type of fuse
has the correct blowing characteristics to protect the triacs - 

do NOT

use any other type of fuse.

The fuse holders are mounted on the back panel for easy access when
the unit is rack mounted.

OTHER INFORMATION

MAINS CABLE REPLACEMENT  -

 This modification

should only be carried out by suitably skilled and competent
persons.

Important - 

the earth wire must be longer than the live and neutral

wires so that the earth will always be the last wire to come off if the
cable is pulled from the unit.    Ensure the outer sheath covering the
live and neutral wires is within 15mm of the live and neutral pads on the
PCB.   Replace the cable ties (Pulsar Part No.4267) which were
removed to allow replacement.

AUDIO INPUTS

 -

 these are not earthed directly within the unit but

through a resistor.   This eliminates earth loops and hence hum and
interference on your sound equipment.  There is an electronic circuit to
enhance the separation between the 'Sound-to-Light' channels.

WARNING - FUSING OF INDUCTIVE LOADS.

   In the unlikely

event of a fault occuring in your unit, it is occasionally possible that
damage could occur to incorrectly fused transformers or ballasts of
inductive loads.   Make sure that your inductive loads are fitted with the
lowest value of anti-surge fuse that does not blow in normal use.   If in
doubt contact Pulsar.   Pulsar cannot be held responsible for damage
to incorrectly fused inductive loads under these circumstances.  

 

Pulsar Pinspots

 are fully protected by self-resetting, solid-state fuses.

WARNING - CAPACITIVE LOADS

  

Remove all Power Factor

Correction capacitors.  Damage to your load may occur if this is not
done.  Pulsar cannot be held responsible for damage to capacitive
loads under these circumstances.  If in doubt contact Pulsar.

INTERFERENCE SUPPRESSION -

  The

 Z4001

 has a

comprehensive choke/capacitor interference suppression system
which reduces the level of interference produced to below the levels
required by EN55014, BS800, VDE0875 etc..   However a small
amount of residual interference always exists with this type of
equipment ,so it is advisable to keep all lighting and mains leads
associated with the 

Z4001

 as far away as possible from sensitive

microphone or guitar pick-up leads and A.M. radios; by doing this we
do not envisage any problems

PORTABLE APPLIANCE TESTING -

 

The

 ZERO 4001

 may be

safely Earth Bond and Insulation (500V) Tested.

STANDARDS - 

The 

ZERO 4001

 complies with the following

International and National Standards:

Electrical Safety

 - IEC65, EN60065, BS415

EMC

 - EN50081-1, EN55014, EN55022, EN50082-1

Rack Mounting

 - IEC297

Index of Protection

 - IP20

Marking

 

Directive 93/68/EEC

 - The 

ZERO 4001

 meets both the

EMC Directive 89/336/EEC and the Low Voltage
Directive 73/23/EEC

GUARANTEE -

 12 months from the date of original

purchase.  The guarantee is limited to parts and labour.  The guarantee
is void if the unit is mis-used, if repairs are performed by unauthorised
persons or the incorrect type of fuse has been used.  In the unlikely
event of a fault occurring, do not use without repair.  Return the unit,
with a description of the fault, to your supplier or direct to Pulsar for
immediate attention.

ACCESSORIES

The following products have been designed to work with and
complement the Pulsar 

ZERO 4001

 Soundlite/Chaser.

Remote Control
Product No.

Accessory

23705

4 Channel Desk

23706

Litefoot - Footswitch

Ventilation Panels

25261/2/3/4

1,2,3 and 4U Ventilation Panels

Wall Mounting Brackets

25033

4U wall mounting 

PULSAR 

also manufactures a comprehensive range of Cables,

Splitter Blocks, Strobes, Dimming and Switching Packs, Control
Desks, Pinspots, and Stage and Rock and Effects Lanterns.  Please
contact us to receive further details of these superb products!

!

Code

Unit

Width Height Depth Weight

 

mm.

mm.

mm.

kgs.

23700XX

ZERO 4001

483.0

86.0

160.0

3.0

23700XX

ZERO 4001 (Inc. Skts)

483.0

86.0

191.0

3.0

Console Cut Out

448.0

80.4

193.0

-

Fixing Holes

465.6

76.3

-

-

Отзывы: