ENGLISH
Selection table for optical device inserts
Ring
Adapter
model
The internal diameter of the insert needs to match the outer
diameter of the objective lens housing of the daylight optical
device it is being installed on.
Insert internal diameter,
mm
Suitable for lens housing of daylight
optical devices with an outer
diameter of, mm
PSP Ring
Adapter 42
mm
45.5
45.5
46
46
46.5
46.5
47
46.7-47.6
48
47.7- 48.6
49
48.7-49.6
50
49.7-50.6
PSP Ring
Adapter 50
mm
51.6
51.6
53.4
53.4
55
54.7-55.6
56
55.7-56.6
57
56.7-57.6
58
57.7-58.6
59
58.7-59.6
PSP Ring
Adapter 56
mm
60
59.7-60.6
61
60.7-61.6
62
61.7-62.6
63
62.7-63.6
64
63.7-64.6
65
64.7-65.6
•
Screw together the Ring Adapter
(12)
and the thermal imaging module along
the threads of the mounting area
(17)
until it stops. Then untighten a little
(no more than one turn) so that the lever
(16)
is on the right side (see Figure).
•
Evenly tighten the screws
(13)
until the ball joint grips in the Ring Adapter
(12)
.
•
Apply 2-3 strips of double-sided tape to the outer surface of the insert
(11)
of your choice.
•
Push the insert
(11)
of your choice into the Ring Adapter
(12)
until it stops.
•
Move the lever
(16)
to the OPEN position.
•
Before installing the Ring Adapter
(12)
onto the optical device, it is
recommended to degrease the lens body of the optical device
(10)
.
•
Mount the Ring Adapter
(12)
with the insert
(11)
onto the lens of the daylight
optical device
(10)
as far as it will go.
•
If the Ring Adaptor
(12)
with the insert
(11)
selected according to the table
cannot be mounted onto the lens
(10)
, follow the steps below:
- Loosen the locking screw
(14)
with a 2mm Allen key.
- Untighten the screw
(15)
with a hex wrench (S = 4mm) until the Ring
Adaptor with the insert can be mounted onto the lens
(10)
.
•
Move the lever
(16)
from its initial OPEN position to the CLOSE position.
•
Loosen the locking screw
(14)
with a 2mm Allen key, if it hasn’t been done before.
•
Tighten the screw
(15)
using a 4mm Allen key. The clamping force should be
1.5-2 Nm (use a torque screwdriver) to ensure the lever is correctly tightened
(16)
, while the Ring Adapter with the thermal imaging module should not
move relative to the body of the optical device
(10)
. If necessary, tighten or
loosen the screw
(15)
to operate the lever
(16)
in the best way possible.
5
Содержание XQ30
Страница 1: ...Quick Start Guide PROTON XQ30 Thermal Imaging Monocular...
Страница 45: ...Open Close 16 12 10 11 13 2 5 3 4 1 8 15 17 9 6 7 14 18 ON 6 REC 7 8 42...
Страница 47: ...LED 20 LED 20 0 25 0 25 26 50 26 50 51 80 51 80 81 99 81 99 10 USB Power Delivery 3 3 4 4 5 4 3 4 3 4 3 5 44...
Страница 50: ...1 ON 6 8 M SA A ON 6 8 ON 6 Stream Vision Stream Vision Wi Fi pulsar vision com 47...
Страница 52: ...pulsar vision com...