1. Technical description

 

 

1.1. General description. 

The SF108-B is dedicated for uninterruptible power supply of 8 IP cameras (52 V DC power supply). 
 
The main elements of this system include: 
- 10 ports PoE (SF108) switch  
- 27,6V (PSB-1552455) buffer power supply with two 17 Ah / 12 V batteries 
- a converter (DC/DC52230) increasing the voltage to 52 V DC (supply of the PoE switch). 
 
In case of power decay, a battery back-up is activated immediately. 
 

         The  approximate  backup  time  is  given  assuming  that  all  output  ports  are  used  (using  typical  devices  and  17  Ah 
batteries).  The  electricity  consumption  for  own  needs  and  the  energy  efficiency  of  the  power  intake  track  were  taken  into 
account. The exact description of how to perform the calculations can be found at: 

"Approximate backup time - assumptions 

for calculations"

.  

 
         Automatic detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 

– 8 ports of the switch. The 

G1/TP and  G2/TP ports is used for connection of another network device via RJ45 connector. The switch is fitted with SFP 
two  slots;  the  use  of  fiber  optic  module  (GBIC)  allows  fiber  optic  transmission.  The  LEDs  at  the  front  panel  indicate  the 
operation status (description in the table. 8). 

 
The switch is housed in a metal enclosure (color RAL 9003) which can accommodate a two 17 Ah/12 V batteries. The 

enclosure features a micro switch tamper indicating door opening (front panel).  
The  SF108-B  is  fitted  with  two  LEDs  on  the  front  panel  (red  LED 

–  indicates  230  V  power  supply  of  the  PSU,  green  LED 

indicates the presence of DC voltage). 

 
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a 

separate  power  cable  for  each  device.  This  method  allows  supplying  other  network  devices,  such  as  IP  phone,  wireless 
access point or router. 

 

1.2  Block diagram. 

 

 

 

Fig. 1. Block diagram. 

 
 
 
 
 
 
 
 
 
 
 

Содержание SF108-B

Страница 1: ...backup time 5h 30min LED indication Metal enclosure color white RAL 9003 with space for two 17 Ah 12 V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requir...

Страница 2: ...ction of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The G1 TP and G2 TP ports is used for connection of another network device via RJ45 connector The switch is fitted with SFP two slots the use of fiber optic module GBIC allows fiber optic transmission The LEDs at the front panel indicate the operation status description in the table 8 The switch is house...

Страница 3: ...er power supply unit PSB 1552455 3 DC DC52230 Step up DC DC converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for two 2 x 17 Ah 12 V connect the batteries in series 7 Power supply connector of the PSU L N Protective connector electric shock 8 BAT BAT battery output BAT red BAT black Fig 3 The view of the switch ...

Страница 4: ...ndwidth 1 6 Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 96 W Table 4 Electrical parameters Supply 200 240 V 50 Hz 1 A Supply power 110 W Output current at the PoE ports RJ45 8 x 0 6 A ΣI 2 A max Output voltage at the PoE ports RJ...

Страница 5: ... licenses applicable and required for a given country for 230 V and low voltage installations The device shall be mounted in confined spaces according to the environment class II with normal air humidity RH 90 max without condensation and the temperature from 10 C to 40 C The switch shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the ...

Страница 6: ... to the terminal marked with the symbol power supply module connector Use a three core cable with a yellow and green protection wire to make the connection Lead the cables to the appropriate clips through the insulating bushing of the connection board 4 Connect the power 230 V 5 Connect the battery mind the colours battery output V BAT cable red battery output 0V BAT cable GND black Caution Connec...

Страница 7: ...ith the IEEE802 3af at standard ON supply Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 Mb s or 100 Mb s and data transmission OFF no connection ON the device is connected 10 Mb s or 100 Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORTS YELLOW LED LIGHT LINK OFF no connection ON the device is connected Blinking data tra...

Страница 8: ...e PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacement use a replacement of the same parameters WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste According to the ...

Отзывы: