background image

 

2.  Installation 

2.1. Installation procedure 

The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and  required  for  

a  given  country)  for  230 V and  low-voltage  installations. It is required to install an installation switch with a nominal current 
of min. 3 A in the power supply circuits outside the power supply unit. 

 
The  device  shall  be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity 

(RH=90% max. without condensation) and the temperature from -

10°C to +40°C.  

The  switch  shall  work  in  a  vertical  position  that  guarantees  sufficient  convectional  air-flow  through  ventilating  holes  of  the 
enclosure.  

 
Before installation, prepare a Switch'a load balance.  

 
The given value of 30 W per port is the maximum value referring to a single output. The total power consumption 

should  not  exceed  48  W. 

The  increased  demand  for  power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or 

infrared illuminators - when launching these features, the power consumption increases rapidly, which may adversely affect the 
operation of the switch. As the device is designed for a continuous operation and is not equipped with a power-switch, therefore 
an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about 
the  method  of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The  electrical  system  shall  follow 
valid standards and regulations.

 

 

2.2.  Installation procedure 

 

 

Before installation, cut off the voltage in the 230 V power-supply circuit. 

To switch power off, use an external switch, in which the distance between the contacts of all 

poles in the disconnection state is not less than 3mm. 

 

 

1. Mount the PSU in a selected location and connect the wires.  
2. Connect the power cables (230 V) to L-N clips of the PSU.  

 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire 

coat of the power cable shall stick to one side of the terminal - 

marked with ‘

 

 symbol on the PSU 

enclosure. Operation of the PSU without the properly made and fully operational shock protection 

circuit is UNACCEPTABLE! It can cause a device failure or an electric shock.

 

 

 

3. Connect the ground wire to the terminal marked with the 

 symbol (power supply module connector). Connect the 

ground wire to the clip marked by the earth symbol 

. Use a three-core cable (with a yellow and green 

 protection 

wire) to make the connection. Lead the cables to the appropriate clips through the insulating bushing of the connection 
board.  
 
4. Connect the battery (mind the colours):   

          - battery output (+V):  BAT+ cable / red, 

- battery output (0V):  BAT 

– cable / GND / black. 

 
 
5. Connect the power (230 V). 
6. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network (the 
UPLINK connector). 
7.  Connect  the  power  supply  of  the  DVR  (by  default,  the  device  is  equipped  with  a  cable  terminated  with  the  
     DC 2.1 / 5.5 plug)  
8. Check the optical indication of the switch operation. 
9. After installing and checking proper working, the enclosure can be closed.     
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание S64-BR

Страница 1: ...me 6h LED indication Metal enclosure color white RAL 9003 which can accommodate two 17Ah 12V batteries Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the productio...

Страница 2: ...ption of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 p...

Страница 3: ...y unit 3 DC DC50SD converter 4 DC DC52115 converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Space for batteries 2 x 17 Ah 12 V connect the batteries in series 8 Power...

Страница 4: ...802 3af at 1 4 ports 52 V DC 30 W at each port Used pairs 1 2 3 6 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication...

Страница 5: ...assembly possible Connectors Power supply of the cameras RJ45 socket Power supply of the DVR DC plug 2 1 5 5 Outputs 0 63 2 50 AWG 22 10 Battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclo...

Страница 6: ...system shall follow valid standards and regulations 2 2 Installation procedure Before installation cut off the voltage in the 230 V power supply circuit To switch power off use an external switch in w...

Страница 7: ...3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel RED LED on the PSU is supplied with 230 V off no 230 V supply GREEN LED on DC voltage in the AUX output o...

Страница 8: ...the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10Mb s or 100Mb s and data transmission OFF...

Страница 9: ...k The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replaceme...

Отзывы: