www.pulsar.pl
PSUPS10A12C
6
Over voltage protection OVP
>16V (automatic return)
Deep discharge protection UVP
U<9,5V (
± 5%) – disconnection of battery terminal
Sabotage protection:
- TAMPER output indicating enclosure
opening
- micro-switches, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Optical indication: front panel of the PSU
- AC OK.; LED indicating the AC power
status
- DC OK.; LED indicating the DC supply at
the PSU output
- red, normal status
– on, failure: off
- green, normal status
– on, failure: off
Table 5. Mechanical specifications.
Dimensions
W=400, H=350, D+D
1
=92+8 [+/- 2mm]
W
1
=405, H
1
=355 [+/- 2mm]
The dimensions of the
battery compartment
180x170x80mm (WxHxD) max
Fixing
See Fig. 3
Net/gross weight
4,3/4,6 kg
Enclosure
Steel plate DC01 1,0mm, colour RAL 9003
Closing
Cheese head screw x 2 (at the front), lock assembly possible
Connectors
Mains supply:
Φ0,63-2,50 (AWG 22-10)
Outputs for cameras
: Φ0,63-2,50 (AWG 22-10)
Recorder outputs: power cord 55cm, terminated with the DC 5,5/2,1 plug
Battery outputs: 6,3F-2,5/40cm
TAMPER output: wires
Notes
The enclosure does not adjoin the assembly surface so that cables can be led.
Table 6. Operation safety.
Protection class PN-EN 60950 -1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input (network) circuit and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100
MΩ, 500V DC
Table 7. Operating specifications
Environmental class
II
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insolation
unacceptable
Vibrations and impulse waves during transport
Wg PN-83/T-42106