www.pulsar.pl 

 

 

 

 

PSDC05125T 

 

 

 

 

 
 

Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input (network) circuit and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000V/AC min. 
1500V/AC min. 
  500V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

 
Operating specifications (tab.6). 

Operating temperature 

-

10ºC...+50ºC  

Storage temperature 

-

25ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 
2. Installation. 
 

2.1 Requirements. 

The  stabilized  PSU  is  to  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses  (applicable 

and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be mounted in 
confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal  relative  humidity  (RH=90%  maximum, 
without condensation) and temperature from -

10°C to +50°C. The PSU shall work in a vertical position that guarantees 

sufficient convectional air-flow through ventilating holes of the enclosure. 
 

During normal operation the total current consumption of the receivers cannot exceed I=5A 

 
 

As the PSU module is designed for a continuous operation and is not equipped with a power-switch, therefore an 

appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user  shall  be  informed 
about the method of unplugging (most frequently through separating and assigning an appropriate fuse in the fuse-box). 
The electrical system shall follow valid standards and regulations. 

 
2.2  Installation procedure. 

 

1. Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 

2. Mount the PSU in a selected location and connect the wires. 
3. Connect the power cables (~230VAC) to L-N terminals of the PSU. Connect the ground wire to the terminal marked by 
the earth symbol. Use a three-core cable (with a yellow and green PE protection wire 

) to make the connection. Lead 

the cables to the appropriate terminals of the connection board through the bushing. 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow and 

green wire coat of the power cable shall stick to one side of the terminal 

marked with the ‘

’ 

earth symbol in the PSU enclosure. Operation of the power supply without a properly made and 
fully operational shock protection circuit is UNACCEPTABLE! It can result in device damage or an 
electric shock. 

 

 
4

. Connect the receivers’ cables to the 

AUX1…AUX5 

connectors

 

on the

 LB5  strips.

 

5. In electrical installations with significant voltage drops in the resistance of the wires that lead to the receivers, the 
voltage value can be corrected with the P1 potentiometer 

(12V÷15V DC). 

6. Check the PSU operating status indication 
7. Once the installation and operation control have been completed, the enclosure can be locked. 

3. Operating status indication. 

The PSU is equipped with LED indication of operation status. The presence of power at the outputs of the 

PSU is indicated by the illumination of green LEDs on the front panel of the device.  

3.1. LED indication  

 

LED1…LED5

 green diodes indicate power at the outputs: 

LB5- 

AUX1…..AUX5. 

In case of a power loss at the output (fuse activation), an appropriate diode goes out. (L1 for AUX1, L2 for 
AUX2 etc.) 