Pulsar PSDC 08128 Скачать руководство пользователя страница 5

www.pulsar.pl 

 

 

 

 

PSDC08128 

 

 

 

 

 
 

1.4. Specifications: 

   - electrical specifications (tab.3) 
   - mechanical specifications (tab.4) 
   - operation safety (tab.5) 
   - operating specifications (tab.6) 

 
Electrical specifications (tab. 3). 

Supply voltage 

176 ÷ 264V AC 

Current consumption 

0,9A@230VAC max. 

PSU power 

120W max. 

Efficiency 

83% 

Output voltage 

12V DC 

Output current 

8 x 1A 

Output voltage adjustment range 

12V÷ 15V DC  

Ripple voltage 

100mV p-p max. 

Short-circuit protection SCP  

LB8/AW STRIP 
8x F 1A fuse or PTC 1A 
PSU MODULE 
105% ÷ 150% of PSU power, electronic current limiting 

Overload protection OLP 

105% ÷ 150% of PSU power, electronic current limiting 

Surge protection 

varistors 

Surge over voltage protection OVP 

>16V (activation requires disconnecting the load or supply for  
about 20 s.) 

Tampering protection system  
- TAMPER 

– indicating unwanted 

opening of the 

PSU’s enclosure 

 
- microswitch, NC contacts (enclosure closed), 0,5A@50V DC (max.) 

Technical outputs: 
- FPS  outputs indicating fuse failure 
(blow) of LB8/AW strips:  (SCP activation) 

 
- OC type, 50mA max, 
normal status: L level (0V), 
failure: hi-Z level 

F1÷ F8 fuses  

F 1A/250V or PTC 1A (manual selection) 

 

Mechanical specifications (tab. 4). 

Enclosure dimensions 

280 x 256 x 60+8 (WxHxD) [mm] (+/- 2) 

Fixing 

See figure 3 

Net/gross weight 

1,96/2,25 kg 

Enclosure 

Steel plate, DC01 0,7mm colour: RAL 9003 

Closing 

Cheese-head screw: at the front 

Connectors 

Power supply: 230V AC: 

Φ0,63-2,05 (AWG 22-12) 

AUX outputs: Φ0,51- 2,05 (AWG 24-12) 
LB8/AW: Φ0,51- 2,05 (AWG 24-12) 
TAMPER output: wires 25cm 

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led. 
Convectional cooling. 

 
Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input (network) circuit and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000V/AC min. 
1500V/AC min. 
  500V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

 
Operating specifications (tab.6). 

Operating temperature 

-

10ºC...+50ºC  

Storage temperature 

-

25ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 

Содержание PSDC 08128

Страница 1: ...PSDC 08128 v 1 2 PSDC 12V 8A 8x1A Power supply for up to 8 analog cameras PTC TOPIC EN Edition 10 from 17 10 2016 Supersedes the edition 9 from 25 05 2015...

Страница 2: ...ion surge protection OLP overload protection against tampering warranty 3 year from the production date Example of power supply of up 8 analog cameras All channels adjustable in the range 12V 15V DC 8...

Страница 3: ...U The PSU is housed in a metallic enclosure with an indication panel featuring a microswitch indicating unwanted opening of the door faceplate 1 2 Block diagram fig 1 Fig 1 Block diagram of the PSU 1...

Страница 4: ...30V AC power connectors PE protection connector 2 LED indication of DC power status main module of the PSU 3 PSU module 4 VADJ potentiometer output voltage adjustment within the range of 12V 15V DC 5...

Страница 5: ...V or PTC 1A manual selection Mechanical specifications tab 4 Enclosure dimensions 280 x 256 x 60 8 WxHxD mm 2 Fixing See figure 3 Net gross weight 1 96 2 25 kg Enclosure Steel plate DC01 0 7mm colour...

Страница 6: ...the connection board through the bushing The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the te...

Страница 7: ...tected against a short circuit by glass fuses or polymer fuses If a fuse assisted protection has been chosen replace the fuse of the same parameters in case of a failure If the polymer fuses assisted...

Отзывы: