WEEE MARK 

 

 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or 

electronic waste as unsorted municipal waste and to collect such WEEE separately.

 

 
 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law.

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pulsar  

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

Содержание PSBOC1552455

Страница 1: ...PSBOC1552455 v 1 1 PSBOC 27 6V 5 5A OC Enclosed buffer switch mode power supply unit with technical outputs EN Edition 9 from 01 03 2018 Supercedes edition 8 from 01 06 2016...

Страница 2: ...ption 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indica...

Страница 3: ...ating DC absence PSU failure relay type 6 LoB output indicating battery low voltage relay type 7 EPS AC absence technical output OC type 8 PSU output indicating DC absence PSU failure OC type 9 LoB ou...

Страница 4: ...tection SCP electronic automatic recovery Overload protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection polymer fuse Surge protectio...

Страница 5: ...tions and impulse waves during transport PN 83 T 42106 2 Installation 2 1 Requirements The buffer PSU is to be mounted by a qualified installer holding relevant permits and licenses applicable and req...

Страница 6: ...accordance with the signs colours 7 Once the tests and operation control have been completed the enclosure cabinet can be locked Fig 3 Mechanical view of the PSU 3 Operating status indication 3 1 LED...

Страница 7: ...In case of decrease of battery voltage UBAT 23V the output is switched into high impedance state hi Z relay output In case of a battery voltage drop UBAT 23V the contacts of the relay change over The...

Страница 8: ...e and to collect such WEEE separately The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable...

Отзывы: