Pulsar PSBD 5012 Скачать руководство пользователя страница 2

 

 

Features of the power supply unit: 

 

 

13.8 VDC uninterruptible power supply  

 

Controlling of the battery charging and 
maintaining 

 

Protecting the battery against excessive 
discharging (UVP) 

 

BAT output is full protected against short-
circuit and reverse connection  

 

Selectable battery charging current 

 

START function of manual battery actuation  

 

Checking the status of safety fuses of AUX 

 

LED optical signalisation  

 

BS outlet for the signalling of the 230V 
network collapse 

 

AW output of power supply unit failure, tripped 
by: 

 

outlet short-circuit (SCP)  

 

outlet overload (OLP) 

 

failure of DC/DC voltage converter 

 

Safety equipment:  

 

SCP short-circuit protection  

 

OLP overload protection  

 

OHP overheat protection  

 

Overvoltage protection  

 

Against sabotage 

 

CONTENTS: 
1. Technical description. 

1.1. General description 
1.2. Block diagram 
1.3. Description of elements and power supply connectors 
1.4. Technical parameters 

2. Installation. 

2.1. Requirements 
2.2. Installation procedure 

3. The power supply operation indication. 

3.1. Optical indication 
3.2. Technical output 

4. Service and operation. 

4.1. Overloads or short circuits to the PSU module  
4.2. Battery assisted operation 
4.3. Maintenance 
 

Information about types: 

Model 

Description 

 

PSBC 5012 
PSU-B-13,8V/S-5A/1/EL-TR-17Ah/MC

 

12V DC buffer (switching) power-supply unit, with the total 
current capacity 5A and output voltage 11,0V-13,8V. Equipped 
with the AC supply absence indication system (battery assisted 
operation), failure and casing sabotage indication system. 

Metal 

casing IP20 with a space for 17Ah/12V battery.

 

 

PSBD 5012 
PSU-B-13,8V/S-5A/1/EL-TR-40Ah/MC

 

12V DC buffer (switching) power-supply unit, with the total 
current capacity 5A and output voltage 11,0V-13,8V. Equipped 
with the AC supply absence indication system (battery assisted 
operation), failure and casing sabotage indication system. 

Metal 

casing IP20 with a space for 40Ah/12V battery.

 

 

PSBE 5012 
PSU-B-13,8V/S-5A/1/EL-TR-65Ah/MC

 

12V DC buffer (switching) power-supply unit, with the total 
current capacity 5A and output voltage 11,0V-13,8V. Equipped 
with the AC supply absence indication system (battery assisted 
operation), failure and casing sabotage indication system. 

Metal 

casing IP20 with a space for 65Ah/12V battery.

 

 
1. Technical description. 
 

1.1. General description. 

The  buffer  power-supply  is  used  for  uninterrupted  supply  of  alarm  systems  devices  requiring  stabilized 

voltage of 

12V/DC (+/-15%). 

The power-supply provides voltage within the following range: 

U= 11,0V÷13,8 V DC 

of 

total  current  efficiency  equal  to 

I=5A. 

In  case  of  power  voltage  decay,  prompt  switching  to  battery  supply  occurs. 

The  power-supply  has  got  a  metal  casing  (RAL  9003  color)  with  a  space  for  40Ah/12V  (42Ah/12V)  battery.  The 
casing features a microswitch indicating door (front) opening and disconnection with the surface. 
 

 

Содержание PSBD 5012

Страница 1: ...PSU B 13 8V S 5A 1 EL TR 40Ah MC PSBD 5012 v 1 1 Buffer switching power supply unit EN Edition 2 from the 21 st June 2010 Supercedes edition 1 from the 21 st April 2009...

Страница 2: ...it with the total current capacity 5A and output voltage 11 0V 13 8V Equipped with the AC supply absence indication system battery assisted operation failure and casing sabotage indication system Meta...

Страница 3: ...ration 2 x converter DC DC 2 5A 5V ADC 255 2 x LB5 AW fuse block AWZ 536 40Ah 2 x voltage reducer RN 2 5A 12V RN250 2 x LB5 AW fuse block AWZ 536 40Ah 1 x voltage reducer RN 5 0A 12V RN500 2 x LB5 AW...

Страница 4: ...5A J1 J2 Ibat 2 0A Legend dip switch installed dip switch removed 8 BAT BAT outputs battery connectors BAT red BAT black 9 TAMPER x2 microswitches contacts contact of antisabotage protection NC 10 F2...

Страница 5: ...5 Fig 2 The view of the power supply...

Страница 6: ...attery circuit SCP and reverse polarity protection 6 3A current limitation F1 fuse failure requires replace of the fuse element Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT batte...

Страница 7: ...and is not equipped with a power switch therefore an appropriate overload protection in the power supply circuit shall be guaranteed Moreover the user shall be informed about the method of isolation o...

Страница 8: ...of illumination is dependent on the charging current AUX green diode indicates the DC supply status at the output of the PSU Under normal status the diode is permanently illuminated and in the case o...

Страница 9: ...he PSU is equipped with the discharged battery disconnection system UPV the configuration of functions through the dip switch JP B The battery protection is on if the dip switch JP B is removed 4 3 Ma...

Страница 10: ...ing of the equipment to the service centre of the manufacturer 7 The repair period mentioned in item 5 may be prolonged if there is no technical capability to carry out the repairs and in the case tha...