Pulsar POE1648 Скачать руководство пользователя страница 3

www.pulsar.pl                                                      POE1648  

                          

 

 

1.  Technical description. 
 

1.1.  General description. 

                The PSU is designed for supply of up to 16 cameras IP requiring stabilized voltage of 

48V DC

.

 

The output 

voltage can be adjusted with a potentiometer between 

41V÷56V DC

. The power is carried over the spare pairs (4/5

 

7/8),  which,  according  to  the  Ethernet  network  standard,  are  not  used  for  data  transmission  (data  transmission 
uses  1/2  and  3/6  data  pairs).  The  PSU  is  housed  in  a  metal  enclosure  with  signaling  panel  equipped  with  a 
microswitch indicating door opening (front cover). 

 

The PSU can not be used in Gigabit Ethernet networks, where all twisted pairs are involved in the 

transmission of data!  

 

1.2.  Block diagram. 

 

 

 

Fig. 1. Block diagram of the PSU. 

 

1.3.  The description of components and connectors of the PSU. 

Table 1. 

Component No. 

[Fig. 2] 

Description 

[1] 

IN 

 screw connection, input power supply of the module (factory setting)

 

[2] 

red LED 

– indicates power 48V DC at the 

IN 

output

 

[3] 

Optional, external optical indication connector (factory setting) 

[4] 

PoE 1 ÷ PoE4

 - Network outputs (Et power supply) 

– for camera connection 

[5] 

LAN 1 ÷ LAN4

 - Network inputs (Ethernet) 

– for connecting the Ethernet network switch 

[6] 

Mounting board 

Table 1. The description of components of the PoE module. 

Содержание POE1648

Страница 1: ...POE1648 v 1 0 PoE 48V 6A PoE power supply for up to 16 IP cameras EN Edition 1 from 09 02 2016 Supersedes the edition ...

Страница 2: ...ection OLP overload protection warranty 2 year from the production date Example of power supply of up 16 IP cameras range 41V 56V DC 16 x 0 35A TABLE OF CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors of the PSU 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Power supply operation indicat...

Страница 3: ...dicating door opening front cover The PSU can not be used in Gigabit Ethernet networks where all twisted pairs are involved in the transmission of data 1 2 Block diagram Fig 1 Block diagram of the PSU 1 3 The description of components and connectors of the PSU Table 1 Component No Fig 2 Description 1 IN screw connection input power supply of the module factory setting 2 red LED indicates power 48V...

Страница 4: ...e switch mode PSU 2 L N power supply connector 230V AC PE protection connector 3 LED light indicating correct operation of the switch mode PSU 4 VADJ potentiometer regulation of the power supply output voltage 41 56V DC 5 PoE module 6 TAMPER microswitch contacts of antisabotage protection NC Tab 2 Components of the PSU see Fig 3 ...

Страница 5: ... 0mm RAL 9003 Closing Cylindrical screw x 2 at the front lock assembly possible Terminals Switch mode power supply Φ0 63 2 05 AWG 22 12 PoE module Φ0 5 2 05 AWG 24 12 LAN1 LAN4 inputs RJ45 8P8C shielded PoE1 PoE4 outputs RJ45 8P8C shielded TAMPER output wires 35cm Notes The enclosure has a 15mm distance from the mounting surface so the cables can be led PSU cooling fan cooling Safety of use Table ...

Страница 6: ...hernet Connections between the power supply and the camera can be done using UTP 3 cable networks with data rates up to 10 Mbit s or UTP 5 cable Due to the lower resistance wiring it is recommended especially at large distances between the power supply and receivers to use UTP 5 cable also for networks with data rates up to 10 Mbit s 2 2 Installation procedure 1 Before installation cut off the vol...

Страница 7: ... In case of power supply overload the output voltage is automatically disconnected which is indicated by turning off the corresponding LED The voltage is restored automatically restored once the fault overload is cleared 4 2 Activation of the overload protection of the power supply unit When the OVP system is activated the output voltage is automatically cut off Restart is possible after disconnec...

Страница 8: ...technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and tran...

Отзывы: