Operation (cont’d)
14
Connecting to LPG Fuel Source
1.Locate the LPG converter on the backside of the generator
2.Attach small end of the Gas Hose to the LPG converter.
3.Connect gas hose to propane fuel source. Do not turn on propane source prior to following the steps
outlined.
Starting the Generator Set
Ground Terminal
Before using generator, a ground wire must be connected to the ground terminal.
The Ground terminal is located on the Front Panel. Before using the ground terminal
consult a qualified electrician.
Ground Terminal Symbol:
The 4500Watt dual fuel generator can be started using the following method.
Recoil Start Method,
1. Ensure that there is no gasoline in the engine. If gasoline was used in
IF USING PROPANE FUEL SOURCE
the most recent operation, start the generator with gasoline source
once running, close the fuel valve lever and allow engine to run until all
remaining gasoline has been used. After the engine stops, continue to
step 2.
2. Ensure that the fuel valve lever is in the CLOSE position.
3. After tank is properly connected, turn on propane fuel source. Refer to
LPG connection procedure.
When using the fuel as LPG, make sure that there is no gasoline in the engine.