Used oil should be disposed of at an approved disposal
site. See your local oil retailer for more information.
CAUTION!
MAINTENANCE
20
•
•
•
•
Checking Spark Plug (See Fig 1
6
)
• Disconnect the spark plug wire from the spark plug.
• Before removing the spark plug, clean the area around its base to prevent debris from entering the engine.
• Clean carbon deposits off the electrode with a wire brush.
• Check the electrode gap and
gently adjust
gap
to 0.762 mm -0 .80 mm (.030 - .031") if necessary.
• Reinstall spark plug and tighten to Torque 22.0 – 26.9 Nm (16-20 ft-lb).
• Reconnect spark plug wire.
• If spark plug is worn replace only with an equivalent replacement part. Spark plug should be replaced
annually.
(BOSCH F7TC, NGK BP6ES, CHAMPION N9YC or
equivalent
)
Changing Oil (See Fig 1
4
)
To clean, remove the air filter cover.
Carefully pull the air filter out by
lifting
along the edges.
Remove dirt from filter by tapping on it or having it blown out. Replace with new filter annually.
Reinstall air filter so that it seals and replace air filter cover.
Air Filter (See Fig 1
5
)
A dirty air filter will reduce the life span of the engine, make it difficult to start the engine, and reduce the unit’s performance.
Oil drainage plug
Fig 1
4
Fig 1
5
Fig 1
6
0.762 -0 .800 mm
•
Run the Generator until the Engine is warm, then shut OFF.
•
Place generator on a level surface.
•
Remove the crankcase dipstick.
•
Place an oil pan underneath the oil drain hole to collect used oil.
•
Remove the oil drain plug and allow oil to drain completely.
•
Reinstall oil drain plug, tighten securely.
•
Carefully add SAE 30 or 10W-30 to empty reservoir until the oil reaches the
threads of the oil fill hole (Crankcase Dipstick hole).
•
Replace crankcase dipstick.
Oil Recommendations
• Do not use special additives.
• Outdoor temperatures
can affect
proper oil viscosity for the engine.
• Use the chart to select the best viscosity for the outdoor temperature range
expected.
-22
-4
14
32
50
68
86
104
-30
-20
-10
0
10
20
30
40
SA
E 3
0
10
W
-3
0
Sy
nt
he
tic 5
W
-3
0
0
W-30
*
**
C
F
Note: *Below 40°F (4°C) the use of SAE 30 will result in hard
starting.**Above 80°F (27°C) the use of 10W-30 may cause
increased oil consumption. Check oil level more frequently