Pulsar PG2200 Скачать руководство пользователя страница 16

Power Management

Start engine without anything connected to generator.

When engine has stabilized, plug in and turn on first load. It is strongly recommended to plug in devices with the largest 

output first and the smallest output last to help prevent overloading the generator.

Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load.

Cold Weather Operation

Under humid conditions where temperatures drop to 40ºF (4ºC) the carburetor and/or crankcase breather system may begin 

to freeze. To prevent icing take the following steps:

1. Replace any old fuel with clean, fresh fuel.

2. Use synthetic 5W-30 or SAE 5W-30 engine oil.  Check oil daily or after every 8 hours of use.

3. Turn fuel valve to the open position.

4. Ensure generator is serviced according to the maintenance schedule under “Maintenance” section of manual.

5. Shelter unit from elements.

OPERATION

1

6

Содержание PG2200

Страница 1: ...Generator Model PG2200 www pulsar products com OPERATOR S MANUAL...

Страница 2: ...Connecting Generator to an Electrical System 10 Operation 11 How to Start Engine 11 Grounding the Generator 11 How to Stop Engine 12 Receptacles and Extension Cords 13 Don t Overload Generator 14 Wat...

Страница 3: ...rder parts receive warranty assistance or other services inquiries you can contact us by internet at www pulsar products com or write to us at The emissions control system for this generator is compli...

Страница 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Страница 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Страница 6: ...will supply the correct rated frequency and voltage WARNING Never modify this unit in any way or modify governed speed Never handle the generator electronic devices or any cord while standing in wate...

Страница 7: ...FEATURES A B C D 7 A ON OFF Start Switch B Voltage Meter C 1 12V DC Output For Charging Batteries Only D 2 120V Receptacles E Circuit Protector F Oil Alert G Grounding Connection E F G...

Страница 8: ...8 FEATURES K H M L H Fuel Tank Vapor Vent I Fuel Valve ON OFF J Choke Level I J K Air Filter L Recoil Starter Grip M Fuel Tank...

Страница 9: ...kcase dipstick to ensure you do not overfill the engine Insert a funnel into the crankcase dipstick hold and carefully add 4 Cycle engine oil SAE10W 30 to empty reservoir until oil reaches the outer e...

Страница 10: ...serious injury or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator...

Страница 11: ...wards engine faster than you can let go which could result in injury Always start the engine and let it stabilize before connecting any electronic devices Disconnect all electronic devices before stop...

Страница 12: ...electrical devices plugged in to the receptacles Turn the fuel valve to the OFF position How to Stop Engine See fig 11 13 Turn the engine ON OFF switch to the OFF position Fig 11 Fig 12 Fig 13 2 Fig...

Страница 13: ...RATION Do not connect 3 phase loads to generator CAUTION 12 Volt 8 3 Amp Output is for charging batteries only WARNING 13 This receptacle has a 13 A main circuit breaker to protect against overload Ex...

Страница 14: ...our back to avoid injury Don t Overload Generator Make sure you can supply enough rated watts and surge watts for all electronic devices connected to the generator Rated watts refer to the power a gen...

Страница 15: ...0 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000 Electric...

Страница 16: ...before plugging in the next load Cold Weather Operation Under humid conditions where temperatures drop to 40 F 4 C the carburetor and or crankcase breather system may begin to freeze To prevent icing...

Страница 17: ...sure the air filter is clean Remove any debris that has collected on the generator and around the muffler and controls Use a vacuum cleaner to pick up loose debris If dirt is caked on use a soft bris...

Страница 18: ...inage plug and allow oil to drain completely Reinstall oil drainage plug tighten securely To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove di...

Страница 19: ...r shop Fuel tank must be empty before replacing fuel filter Run unit until tank is empty if needed or inspect filter prior to fill up CAUTION Spark Arrestor See Fig 18 If Appicable Inspect the spark a...

Страница 20: ...ing you to access the petcock When the fuel has drained from the tank close the fuel valve and reinstall fuel line securely on petcock Reinstall the fuel valve knob in the valve bracket Push forward u...

Страница 21: ...er in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded...