www.pulsar.pl                                                                                        MSRK2512 

   

 

 

 

The  PSU  module    is  equipped  with  the  discharged  battery  disconnection  system  (UVP), 

the configuration of functions through the dip switch P

BAT

. The battery protection is on if the dip 

switch P

BAT

 is removed. 

 

4.3 Maintenance 

Any and all maintenance operations may be performed following the disconnection of the PSU module  from the 

power supply  network. The PSU module  does  not require performing any  specific maintenance measures,  however, in 
the  case  of  significant  dust  rate,  its  interior  is  recommended  to  be  cleaned  with  compressed  air.  In  the  case  of  fuse 
replacement, only the substitutes in conformity to the original ones are allowed.

 

 

        WEEE MARK 

According to the EU WEE Directive – It is required not to dispose of electric or electronic waste as 

unsorted municipal waste and to collect such WEEE separately. 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law. 

 
 
 

 

THE GENERAL WARRANTY CONDITIONS 

 
1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a five-years warranty for the equipment, counted from the 
device’s production date. 
2.  The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, 
unless such defects have been reported within the warranty period (item 1).  
3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main 
office of the manufacturer.  
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description 
of the defect.   
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest 
convenienve, however not later that within 14 days from the delivery to the service centre of the manufacturer.  
6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the 
repairs, or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, 
exclusively.  
8. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 
- use that violates the operation manual or equipment’s intended use 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical 
agents,  
- improper installation and configuration (in defiance with the manual), 
9. The warranty is void in any of the following circumstances: 
- construction changes  

 

- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined 
according to the wholesale prices suggested by the manufacturer on the day of purchase.  
11. The manufacturer takes no reponsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to 
abide by the recommendations and requirements contained in the manual, or the use of the equipment.  

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

Содержание MSRK 2512

Страница 1: ...MSRK 2512 v 1 1 MSRK 13 8V 2A Buffer PSU module swith mode EN Issue 3 from 16 09 2013 Supersedes the edition 2 from 16 12 2011 ...

Страница 2: ...ram 1 3 Description of elements and connection links of the PSU module 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Installation procedure 3 PSU module operation indication 3 1 Optical indication 3 2 Technical output 4 Handling and operation 4 1 Over loads or short circuits to the PSU module 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General descript...

Страница 3: ...eter voltage adjustment DC 4 FBAT fuse in the battery circuit 5 Connectors BAT DC supply output of the battery BAT red BAT black AUX DC supply output AUX U AUX GND FAC technical output for no AC network relay type In Figure 2 configuration of contacts shows relay voltage free state which corresponds to the state signalling no AC network 6 Optical signaling LED AC LED diode that indicates the prese...

Страница 4: ...wels x 4 PCB fi 4 2 mm Net gross weight 0 08kg 0 13kg Connectors Outputs Ф0 41 1 63 AWG 26 14 Battery output BAT 6 3F 2 5 30cm Operation parameters tab 5 Operation temperature 10ºC 40ºC Storage temperature 20ºC 60ºC Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolation unacceptable Vibrations and impulse ...

Страница 5: ...osure cabinet etc 3 PSU module operation indication 3 1 Optical indication The PSU module is equipped with three diodes indicating operation status AC LB AUX AC red diode under normal status AC supply the diode is permanently illuminated The absence of AC supply is indicated by the AC diode going off LB red diode indicates the battery charging process the intensity of illumination is dependent on ...

Страница 6: ...the defect 5 Should the claim be accepted the manufacturer is obliged to provide warranty repairs at the earliest convenienve however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted du...

Отзывы: