background image

 

 

3. Operation indication.

 

 

Table 3. Operation indication 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

GREEN LED LIGHT (Power) 
Indication of the switch's power 
supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION AT THE PoE PORTS (1

÷4) 

 
GREEN LED LIGHT (PoE) 
Indication of the PoE power supply 
at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant with 

the IEEE802.3af/at standard) 

ON

 

– power supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices 10/100Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected 10/100Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UP LINK PORTS  

GREEN LED LIGHT (5) 
The connection status of LAN 
devices and data transmission 

 
 

OFF

- the device no connection 

ON 

- the device is connected  

Blinking

 

– data transmission

 

GREEN LED LIGHT (6) 
The connection status of LAN 
devices and data transmission 

 
 

OFF

- the device no connection 

ON 

- the device is connected  

Blinking

 

– data transmission

 

 

 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household waste. 

According to the European Union WEEE Directive, waste electrical and electronic equipment should be 

disposed of separately from normal household waste

 

 

 
 

 
 
 

 
 

 
 
 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 

Pulsar sp. j. 

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 

Содержание ISFG64

Страница 1: ...supply IP cameras operating in IEEE 802 3af at standard Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch UP LINK ports marked 5 and 6 are used to connect further network devices using fiber optics using SFP modules GBIC On front panel there is LEDs signaling of the device s status description in table below Device has solutions that allow...

Страница 2: ...1 Block diagram 1 3 Description of components and connectors Table 1 See Fig 2 Component No Fig 2 Description 1 4 x PoE ports 1 4 2 2 x UP LINK ports SFP 3 Power Socket V1 V2 4 Holder for DIN rail Fig 2 The view of the switch ...

Страница 3: ...e flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The switch load balance should be done before installation Depending on application appropriate power supply should be selected PoE available only at 48 57 V 52 V recommended The given value of 30 W per port is the maximum value referri...

Страница 4: ...4 Connection schemes ...

Страница 5: ...ion ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UP LINK PORTS GREEN LED LIGHT 5 The connection status of LAN devices and data transmission OFF the device no connection ON the device is connected Blinking data transmission GREEN LED LIGHT 6 The connection status of LAN devices and data transmission OFF the device no connection ON the device is connecte...