Pulsar HPSB 3512B Скачать руководство пользователя страница 3

www.pulsar.pl                                                                 HPSB3512B                                              

GREEN POWER

 

 

3

 

1.2 Block diagram (fig.1).  
 
 

 

Fig.1. The block diagram of the PSU. 

 

1.3 Description of PSU components and connectors (tab.1, tab. 2, fig. 2).

 

Part no. 

 [Fig. 2] 

Description 

[1] 

PSU module 

[2] 

connectors (see: tab.2) 

[3] 

green LED 

indicates AC power 

[4] 

P1 potentiometer,  

output voltage adjustment 

[5] 

BAT+/GND:  battery outputs

 + BAT=red, - GND=black 

[6] 

TAMPER,  

contact, sabotage protection

 (NC) 

[7] 

Additional connector for LED indication

 

Tab.1. The components of the PSU. 

 

 
 

Part  

 [Fig. 2] 

Description 

L, N 

L-N  

power supply connector  

PE 

PE protection connector (electric shock protection) 

V+ 

V- 

DC supply output   
DC supply output (GND) 

Tab.2. Output terminals of the PSU. 

 

Содержание HPSB 3512B

Страница 1: ...HPSB 3512B v 1 0 HPSB 13 8V 3A 7Ah Buffer switch mode power supply unit EN Edition 1 from 19 02 2016 Supercedes the edition...

Страница 2: ...status 4 Operation and use 4 1 Overload or short circuit of the PSU output SCP on 4 2 Disconnection of discharged battery 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU i...

Страница 3: ...ab 2 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact sabotage protection NC 7 Additional connector for LED indi...

Страница 4: ...refer to chart 1 Voltage adjustment range 12 14VDC Ripple 120mV p p max Battery charge current 0 5A max 7Ah 5 Short circuit protection SCP electronic automatic return Overload protection OLP 105 150 o...

Страница 5: ...in 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or protection circuit 100 M 500V DC Operating parameters tab 6 Operating temperature 10 C 40 C see chart 1 Storage...

Страница 6: ...L N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the a...

Страница 7: ...d with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and a...

Страница 8: ...14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the...

Отзывы: