The image is blurry,
with vertical stripes
and uneven
background.
The image is too
dark.
Poor image quality /
Detection range
reduced.
Calibration is required.
Brightness or contrast level
is too low.
Problems described may arise in adverse weather conditions
(snow, rain, fog etc.).
Carry out calibration according
to Section
“SENSOR CALIBRATION”.
Adjust brightness/contrast with
the UP/DOWN buttons.
Smartphone or tablet
PC cannot be
connected to the
device.
Password in the unit was
changed.
Delete network and connect
again inserting the password
saved in the device.
Smartphone or tablet
PC cannot be
connected to the
device.
Password in the unit was
changed.
Delete network and connect
again inserting the password
saved in the device.
No Wi-Fi signal or
erratic signal.
The unit is beyond reliable
Wi-Fi range.
There are obstacles between
the device and the signal
receiver (i.e. concrete walls).
Place the device in line-of-sight
of the Wi-Fi signal.
There are too many Wi-Fi
networks in the area where the
scope is located which may
cause signal interference.
To ensure stable Wi-Fi
performance, move the
riflescope to an area with few
or no Wi-Fi networks.
The device cannot
be powered on
with wireless remote
control.
Remote control is not
activated.
Low battery.
Activate the remote control
according to instructions.
Install a new CR2032 battery.
When using the
scope at below zero
temperatures the
image quality is
worse than at
positive
temperatures.
Because of variations in thermal conductivity, objects (surrounding
environment, background) under observation become warm more
quickly at above-zero temperatures, which allows higher
temperature contrast and, thus, the quality of the image produced
by a thermal imager will be better.
At low operating temperatures, objects under observation
(background) normally cool down to roughly identical
temperatures, which leads to lower temperature contrast, and to
image quality (precision) degradation. This is normal for thermal
imaging device.
Follow the link to read FAQs on thermal vision
http://www.pulsar-nv.com/support/faq/
Check
Corrective action
Problem
26
25
Color stripes appear
on the display or
images disappears.
The device has accumulated
static charge during
operation.
As soon as the impact of the
static charge is over, the device
may reboot automatically;
alternatively please turn off and
restart the device.