background image

www.pulsar.pl                                                      HPSBOC7012C                                                             

GREEN POWER plus

 

 

 

2

 

Features: 

 

 

DC 13,8V/6A uninterruptible power supply*  

 

fitting battery: 17Ah/12V  

 

wide range 

of mains supply: 176÷264V  

 

high efficiency 80% 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

 

jumper selectable battery charge current 1A/2A 

 

battery output full protection against short-circuit 
and reverse polarity connection  

 

LED indication  

 

 

EPS technical output indicating AC power loss  

     

– OC and relay type 

 

PSU technical output indicating PSU failure       

      

– OC and relay type 

 

LoB technical output indicating battery low voltage   
– OC and relay type 

 

protections: 

 

SCP short-circuit protection 

 

OVP overvoltage protection 

 

overvoltage protection  

 

against sabotage 

 

overload protection (OLP) 

 

warranty 

– 2 year from the production date 

 

CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors. 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 
3.2 Technical outputs

 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output (SCP on) 
4.2 

Battery-assisted operation 

4.3 Maintenance 

 

 
1. Technical description. 
 

1.1 General description. 

A buffer PSU is intended for an uninterrupted supply to devices requiring stabilized voltage of  

12V DC (+/-15%).

 The PSU provides voltage of 

U=13,8V DC.

 Current efficiency: 

 

1.  Output current 6A + 1A battery charge

*

 

2.  Output current 5A + 2A battery charge

*

  

  Total device c battery: 7A max

*

 

In case of power decay, a battery back-up is activated immediately. The PSU is constructed based on the 

switch mode PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which 
can accommodate a 17Ah/12V battery. A micro switch indicates door opening (front cover). 

 

OPTIONAL POWER SUPPLY CONFIGURATIONS:  

(visualisation available at: www.pulsar.pl) 

 
BATTERY 17Ah:

 

1. Buffer power supply unit HPSBOC 13,8V/4x1,5A/17Ah. 

- HPSBO  LB4 4x1,5A (AWZ576) + 17Ah 

2. Buffer power supply unit HPSBOC 13,8V/6x1,0A/17Ah.

 

- HPSBO  LB8 6x1,0A (AWZ580 or  AWZ579) + 17Ah 

3. Buffer power supply unit HPSBOC 13,8V/8x0,5A/17Ah.

 

- HPSBO LB8 8x0,5A (AWZ578 or AWZ580) + 17Ah  

4. Buffer power supply unit HPSBOC 13,8V/12V/5A/17Ah.

 

- HPSBO RN500 (13,8V/12V) + 17Ah 

5.

 

Buffer power supply unit HPSBOC 13,8V/12V/4x1A/17Ah.

 

- HPSBO RN500 (13,8V/12V) + LB4x1A (AWZ575 or AWZ576) +17Ah 

                                                 

*

 

See chart 1

 

Содержание GREEN POWER PLUS HPSBOC 7012C

Страница 1: ...HPSBOC 7012C v 1 1 HPSBOC 13 8V 6A 17Ah OC Buffer switch mode power supply unit with technical outputs EN Edition 9 from 01 03 2018 Supercedes edition 8 from 01 06 2016 GREEN POWER plus...

Страница 2: ...load or short circuit of the PSU output SCP on 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to de...

Страница 3: ...he PSU 1 3 Description of the module s components and connectors Table 1 Elements of the module s see fig 2 Element no Description 1 LED indicating presence of AC power 2 LED indicating presence of DC...

Страница 4: ...ER plus 4 Fig 2 The view of the PSU Description of PSU components and connectors tab 2 fig 3 Element no Fig 3 Description 1 PSU module 2 TAMPER contact sabotage protection NC Tab 2 Output terminals of...

Страница 5: ...ction polymer fuse Surge protection varistors Overvoltage protection OVP 16V automatic recovery Excessive discharge protection UVP U 9 5V 5 disconnect of connection battery Tampering protection system...

Страница 6: ...protection circuit 100 M 500V DC Operating parameters tab 6 Operating temperature 10 C 40 C see chart 1 Storage temperature 20 C 60 C Relative humidity 20 90 without condensation Vibrations during ope...

Страница 7: ...nd green wire coat of the power cable shall stick to one side of the terminal marked with symbol on the PSU enclosure Operation of the PSU without the properly made and fully operational shock protect...

Страница 8: ...V In case of absence of DC voltage at the output e g short circuit the output is switched into high impedance state hi Z relay output In case of a failure the contacts of the relay change over CAUTION...

Страница 9: ...o a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5V at the battery terminals will caus...

Страница 10: ...l waste and to collect such WEEE separately The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the appl...

Отзывы: