Pulsar GREEN POWER CCTV PoE POE044816 Скачать руководство пользователя страница 4

www.pulsar.pl                                                      POE044816   

GREEN POWER CCTV PoE

 

 

 

 

 

Fig. 3. The view of the PSU. 

 

Component No. 

[Fig. 3] 

Description 

[1] 

The module of the switch mode PSU 

[2] 

LED light indicating correct operation of the switch mode PSU 

[3] 

V1 ADJ potentiometer – regulation of the power supply output voltage 

[4] 

PoE module 

[5] 

TAMPER – microswitch (contacts) of antisabotage protection (NC) 

Tab. 2. Components of the PSU (see Fig. 3). 

 
 

1.4 Technical parameters. 
- electrical parameters (Table 3) 
- mechanical parameters (Table 4) 
- safety of use (Table 5) 
- operation parameters (Table 6) 

 Electrical parameters (Table 3). 

Mains supply 

88÷264V AC  

Current consumption 

1,2A@230V AC typ. 

PSU’s power 

76,8W max. 

Efficiency 

89% 

Output voltage 

48V DC 

The adjustment range of the output voltage 

42÷54V DC 

Output current  

4 x 0,4 A  

Ripple voltage  

200 mV p-p max. 

Short-circuit protection SCP 

electronic 

Overload protection OLP 

4 x F 0,5A or 4 x PTC 0,5A (jumper selectable) 

Overvoltage protection OVP 

55,2÷64,8V DC 

Surge protection 

4 x varistor 

Antisabotage protection: 

 

Содержание GREEN POWER CCTV PoE POE044816

Страница 1: ...POE044816 v 1 0 PoE 48V 4x0 4A Switch mode power supply unit for CCTV EN Edition 1 from 28 10 2013 Supersedes the edition GREEN POWER CCTV PoE...

Страница 2: ...ice and operation 4 1 Overload or short circuit of the power supply output 4 2 Maintenance 1 Technical description 1 1 General description The PSU is designed for supply of up to 4 webcams requiring s...

Страница 3: ...e AUX1 AUX4 F500mA circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal operation these LEDs are on 6 Network outputs Ethe...

Страница 4: ...chnical parameters electrical parameters Table 3 mechanical parameters Table 4 safety of use Table 5 operation parameters Table 6 Electrical parameters Table 3 Mains supply 88 264V AC Current consumpt...

Страница 5: ...ngth between input network circuit and the output circuits of the PSU I P O P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC m...

Страница 6: ...with a yellow and green PE protection wire to make the connection The power cables should be connected to the appropriate terminals on the connection board through the bushing The shock protection ci...

Страница 7: ...ED is permanently illuminated L1 L4 green LEDs Fig 2 component 5 indicate voltage at the individual outputs of the module L1 for AUX 1 etc Activation of the short circuit overload protection of a give...

Страница 8: ...nufacturer 4 The warranty applies to complete equipment accompanied by a properly filled warranty claim with a description of the defect 5 Should the claim be accepted the manufacturer is obliged to p...

Отзывы: