Control Functions
Preparing Your Generator
2) "OFF"
When the energy saving switch is set to the "OFF" position, the
engine will run at rated speed, regardless of connected load.
Fuel Tank Cap
Remove fuel tank cap by unscrewing it counterclockwise.
AC Circuit Breaker
If the total AC load exceeds the rated current, the AC circuit
breaker will open (trip) and the button will pop out. In this case
disconnect all loads, restart the generator and push in the AC
circuit breaker(s).
Grounding Terminal
If grounding is required by code or application, follow the
guidelines on page 10.
Engine Oil
Your generator ships without engine oil. Do not attempt to start the
generator without sufficient engine oil in the crankcase.
1
)
Place your generator on a flat, stable surface.
2
)
Unscrew the knob
①
to remove oil access cover
②
3
)
Unscrew oil dipstick
③
.
CIRCUIT BREAKER
Gasoline is highly flammable and toxic. You must read and
understand ALL safety instructions before fueling your
generator.
Do not overfill the fuel tank! Heat and vibration can cause
fuel to leak from an over-filled fuel tank.
After refueling, confirm that the fuel tank cap has been
tightened.
DANGER
1 2
3
4
)
Use a funnel to add 12 fluid ounces (0.35L) of 10w-30
engine oil to the crankcase, verify oil level with the dipstick.
5
)
Reassemble oil access cover and tighten the knob.
Pre-use inspection
Fuel
Check fuel level; add if necessary.
Oil
Check oil level; add if necessary. Check for any oil leaks.
Gasoline
Even when not in use the generator is potentially hazardous.
Follow the checklist below before starting the generator. If any
problems are found, do not use the generator until it has been
repaired by an authorized Pulsar Products Service Center.
NOTICE