When changing the viewing distance, try to see a sharp and high-
quality image by rotating the objective lens
and brightness
(1)
adjustment wheel
. Do not rotate the eyepiece
(5)
- the device has
(2)
already been individually adjusted.
In low light conditions or in complete darkness you may switch on the
built-in IR Illuminator
(10)
by pressing the
“IR”
button
(4)
. The laser
IR considerably increases detection and identification range.
To switch between power levels of the IR Illuminator, press
continuously the
“IR”
button
(4)
. Power level
(from 1 to 3)
is shown in the bottom left corner of the display.
To switch the IR Illuminator off, press and hold the
“IR”
(4)
button for
two seconds. Icon appears.
To transmit the observed image to an external monitor or recording
video, plug one jackplug of the video cable (supplied) into Digiforce's
video output
and the second jack plug
(AV OUT)
to an external
(12)
device (function is only available for models
78094, 78095, 78097
)
.
USING THE RANGE FINDING RETICLES
6
Digiforce monoculars are equipped with range finding reticles designed
to estimate approximate distance to an object with known size.
Press the
(3)
button to select a reticle with one of the reference objects
whose sizes are roughly equal to the size of the actual object under
measurement:
1) Reference object
“Hare
” – height 0.3m
2) Reference object
“Wild hog”
– height 0.7m
3)
Reference object
“Deer”
– height 1.7m
Align the imaginary line just underneath the animal's hooves
/legs
with
the large horizontal line in the lower half of the distance-measuring
reticule.
Select the tick mark that corresponds to the height of the animal being
observed.
Now you can determine the distance in meters by reading the number
next to the tick mark.
To switch between the reticles press briefly the button
(3)
Icon of the corresponding reference object is shown in the lower part
of the display.
“
n
”
“
n
”
ACCESSORIES
7
To deactivate the range
finding reticle, press and
hold the
(3)
button for two
seconds.
“
n
”
The Digiforce is equipped with a special mount
(7)
designed to attach
various accessories such as auxiliary IR Illuminators (LED IR Illuminators
Pulsar-805/ Pulsar-940 / Pulsar X-850
or laser IR Illuminators
Pulsar L-915/ Pulsar L-808S
). The unit also has a ¼” standard socket to
be mounted on a tripod. The tripod adapter
(8)
(bought separately) allows
the IR Illuminator to be installed and the unit to be mounted on a tripod
(see pic).
PECULIARITIES OF OPERATION
8
Turn the device off when not in use and when carrying the unit. The device
can be used in daylight as well as nighttime conditions. However, do not
point the device towards bright sources of light.
After using the device in cold temperatures, please, wait up to 2-3
hours before using the device in the warm temperatures.
This helps
prevent condensation on the lenses.
Do not leave the device in direct sunlight. Do not submerge in
water.
Do not subject the digital NV device to shock or impact. Do not drop.
Sand, dust, and salt can damage the device.
Do not connect any non-recommended accessories (headphones,
for example) to the “Video Out” port.
This may damage the device
and void any guarantee.
When focusing on the display (you can see a fine black net) a
maximum of seven light or dark spots on the whole field of view in the
image plane is acceptable.
-150
100
75
50
30
20
15
-
-
-
-
-
-