Stand Alone Settings View/Change (continued) 

To View/Change the Stand Alone Settings, press the 

ñ

 or 

ò

 keys 

on the 

UIM

 until the display shows

  Stand Alone Settings 

View/Change. 

Press the 

X (change)

 key on the 

UIM

, then select the channel to 

view/change using the 

ï

 or 

ð

 

keys.  These keys repeat if held 

down.  When the channel to be viewed/changed is showing in the 
display, press the 

ñ

 or 

ò

 keys to change the value.    These keys 

repeat if held down.  The display shows both the bit number (0-255) 
and percentage (0-100%). 
Please see the 

Chase Select Table

 when modifying chases. 

To modify further channels, select the channel to view/change using 
the  

ï

 or 

ð

 

repeat keys, pressing the 

ñ

 or 

ò

  repeat  keys  to 

change the value. 
When you have finished modifying channels, press the 

ü

 

(Yes)

 key 

to save changes or 

X (Back)

 key to restore the previous settings. 

?  VIEW(Sig)/SET(NoSig) Chan Levels 

To View the Channel Levels/Change the Stand Alone Settings, press 
the 

ñ

 or 

ò

 keys  on the 

UIM

 until the display shows

 

VIEW(Sig)/SET(NoSig) Chan Levels 

Press the 

X (change)

 key on the 

UIM

, then select the channel to 

change/view using the  

ï

 or 

ð

 

keys.  These keys repeat if held 

down. 
When the channel to be changed/viewed is showing in the display, 
press the 

ñ

 or 

ò

 keys to change the value.    These keys repeat if 

held down.  The display shows both percentage (0-100%) and bit 
number (0-255), and for channels 4 (Chase 1 Select) and 7 (Chase 2 
Select) the chases selected. 
Please see the 

Chase Select Table

 when modifying chases. 

Notes: 

 this menu item is for this session use only, data is never saved. 

 the values can only be changed if the unit is not receiving data. 

 pressing the 

X

 or 

ü

 keys returns to the main menu. 

?  Restore Factory Default Settings 

To restore the factory default settings, press the 

ñ

 or 

ò

 keys on the 

UIM

 until the display shows

 Restore Factory Default Settings. 

Press the 

X (change)

 key on the 

UIM

, then press the 

ü

 

(Yes)

 key to 

restore defaults or 

X (Back)

 key to exit. 

The factory default settings are 

DMX Address

 

ChromaZone Mode

 

46 Channel 

Channels per Fixture

 

3 (CFLD) / 9(CBAT) 

Fixture number

 

Chase patterns

 

12 Way 

Channel 10

 

Grand Master for the 36 RGBs only 

Input Smoothing

 

ON 

Low Voltage Supply

 

ON 

DMX Line Termination

  OFF 

If NoSignal use:

 

Stand Alone Mode 

Stand Alone Settings

 

Ch.1 – 3  

=     0 bits /     0% 

 

Ch.4 = Chase 1 Select  = Auto Chase 

 

Ch.5 = Chase 1 Speed  = 128 bits /   50% 

 

Ch.6 = Chase 1 Level  = 255 bits / 100% 

 

Ch.7 – 46  

=     0 bits /     0% 

Failure of the internal

  ChromaFlood or ChromaBatten 5 Amp, 

5x20mm  Power Supply  Fuse,

 usually indicates an internal fault 

requiring servicing by a qualified engineer. 

If the front glass becomes cracked or broken, disconnect from the 
mains immediately and have the unit repaired.  Replacement glasses 
are available from Pulsar. 

The  PMX/DMX connections  (input and  thru) are protected against 
inadvertent shorts to 240Vac and static damage. 

PORTABLE APPLIANCE TESTING  - 

The 

Pulsar

 

ChromaFlood and ChromaBatten

 may be safely Earth Bond and 

Insulation Tested. 

STANDARDS  - 

The 

Pulsar ChromaFlood and ChromaBatten 

comply with the following International and National Standards: 

Electrical Safety - 

IEC65, EN60065, BS415 

EMC

 - EN50081-1, EN55022, EN50082-1 

Index of Protection

 – IP65 

 Marking

 

Directive 93/68/EEC  - 

The 

Pulsar 

ChromaFlood and ChromaBatten

  both meet the 

EMC Directive 89/336/EEC and the Low Voltage 
Directive 73/23/EEC. 

 
Conforms to: 

ANSI/UL Standard 6500

 

Certified to:    

CAN/CSA-E60065-00 

 

 
 
GUARANTEE - 

12 months from the date of original purchase.  The 

guarantee is limited to parts and labour.  The guarantee is void if the 
unit is misused, the cable connections are not in a dry environment or 
made using an IP68 rated connector, or unauthorised persons 
perform repairs.  In the unlikely event of a fault occurring, do not use 
without repair.  Return the unit to your  supplier with a description of 
the fault, or direct to Pulsar for immediate attention 

DIMENSIONS AND WEIGHTS 

 

 

 

 

 

 

Code 

Unit 

Width  Height  Depth Weight 

 

 

mm 

mm 

mm 

kg 

CFLD200  ChromaFlood200

 

365.0  373.0  118.0  8.0 

CBAT200  ChromaBatten200 

1198.0  132.0  132.0  12.4 

OTHER INFORMATION 

CHROMAFLOOD 

CHROMABATTEN 

Содержание Chromabatten CBAT100

Страница 1: ...ChromaFlood and ChromaBatten have a colour code letter This signifies the finished colour of the fixture B Black S Silver Other colours may become available please check with Pulsar if required The ChromaFlood and ChromaBatten have a thermal management system This progressively reduces the power to the LEDs if the internal temperature exceeds limits set by the software Excess temperature will occu...

Страница 2: ...he UIM then select 6 or 12 way using the ñ or ò keys When the required chase pattern way number shows in the display press the ü Yes key to save changes or X Back key to restore the previous settings Channel 10 may be set as a Grand Master for the 36 RGB channels only OR as a Global Grand Master for the 36 RGB channels the ALL Red Green and Blue and the Chase Levels To set the required Ch 10 mode ...

Страница 3: ...store Factory Default Settings Press the X change key on the UIM then press the ü Yes key to restore defaults or X Back key to exit The factory default settings are DMX Address 1 ChromaZone Mode 46 Channel Channels per Fixture 3 CFLD 9 CBAT Fixture number 1 Chase patterns 12 Way Channel 10 Grand Master for the 36 RGBs only Input Smoothing ON Low Voltage Supply ON DMX Line Termination OFF If NoSign...

Страница 4: ...ChromaFlood100 and ChromaFlood200 Mechanical Details ...

Страница 5: ...xture 12 Blue 42 Fixture 6 Blue 2 42 Fixture 4 Blue 3 46 Channel Mode 3 Channels Fixture 6 Channels Fixture 9 Channels Fixture 1 9 as 9 Channel Mode 1 9 as 9 Channel Mode 1 9 as 9 Channel Mode 10 36xRGBGrand Master 10 36xRGB Grand Master 10 36xRGB Grand Master OR OR OR 10 Global Grand Master 10 Global Grand Master 10 Global Grand Master 11 Fixture 1 Red 11 Fixture 1 Red 1 11 Fixture 1 Red 1 12 Fix...

Страница 6: ...1 14 89 228 Rainbow Strobe 13 86 220 White Any Colour Strobe Channels 1 2 3 set colour 83 212 White Any Colour Crossover Channels 1 2 3 set colour 12 80 204 Blue Yellow Wave Reverse 77 196 Blue Yellow Wave Forward 73 188 Green Magenta Wave Reverse 11 70 180 Green Magenta Wave Forward 67 172 Red Cyan AnyCol Op Col Wave Forward 10 64 164 Red Cyan AnyCol Op Col Wave Reverse Channels 1 2 3 set colour ...

Страница 7: ...hing t Low Voltage Supply is t DMX Line Termination t VIEW Sig SET No Sig Chan Levels DMX Address n Receiving t X Change X Restore If NoSignal use t Stand Alone Sett ings View Change ChromaZone Mode nn Channels 3 6 9 10 36 42 46 3 6 FLOOD 9 BATTEN 1 12 of 12 1 6 of 6 FLD 1 4 of 4 BAT 6 Way 12 Way CH10 36xRGB GM CH10 Global GM ON Gentle Smooth OFF Fast Video ON OFF ON OFF Stand Alone Mode Last DMX ...

Страница 8: ... apparatus before lightning storms or when unused for long periods Refer all servicing to suitably qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped...

Страница 9: ...the internal temperature exceeds predefined limits When mounting the ChromaBatten300 at an angle other than horizontal it is essential that the cable end is at the lowest point and the display at the top as shown in the picture to the left This mounting arrangement locates the internal temperature sensor at the hottest point the top Failure to observe these essential mounting arrangements may resu...

Отзывы: