CFLD100

 

-  ChromaFlood100  – 5,8,25,45,12x25,10x90

 

lenses

CFLD200

 

-  ChromaFlood200  – 8,25,45,12x25,10x90 lenses 

CBAT100

 

-  ChromaBatten100 – 10, 25 and 45 degree lenses 

CBAT200

  -  ChromaBatten200 – 10, 25 and 45 degree lenses 

CBAT300

  -  ChromaBatten300 – 10, 25 and 45 degree lenses 

The 

ChromaFlood

 and 

ChromaBatten

 contain state of the art, high 

brightness, high efficiency Red, Green and Blue LEDs.  These three 
primary colours can be mixed together to make an incredible palette 
of 16.7 million colours. 
They are IP65 rated fixtures and therefore suitable for outdoor or 
indoor use. They are powered directly from 100-240 Volts AC and 
have full remote DMX control of RGB levels or can function in Stand 
Alone Mode.  Numerous chases and sequences are built in, enabling 
superb lighting effects without complicated programming. 
These impressive fixtures are ideal for the architectural and 
entertainment markets to give an unlimited colour palette that can 
enhance building facades, water features and focal displays or to 
providing stunning dynamic colour in shows, conferences, concerts 
and themed environments. 
Like the 

ChromaBank,

 the 

ChromaFlood and ChromaBatten

 

contain a 

PULSAR ChromaZone

 controller and can therefore also 

operate in 3, 6, 9, 10, 36, 42 or 46 Channel Modes. 
It is useful to consider the 

ChromaFlood

 as being 1 of the 12 

fixtures, and the 

ChromaBatten

 as being, either 1 or 3, of the 12 

fixtures, within a 

ChromaBank

Please see the 

Channel Assignments Tables 

sheet for details of 

the different modes. 
The 

ChromaFlood and ChromaBatten

 have numerous chases and 

effects built in, making it possible to achieve fantastic effects without 
programming.  These internal effects can be selected via the 

User 

Interface Module

 (UIM) on the rear of the units whilst in Stand Alone 

mode, or from a controller using a digital 

PMX

 (

P

ulsar 

M

ultiple

X

) or 

DMX

 (

D

igital 

M

ultiple

X

) signal. 

Please see the 

Menu Selection Overview

 sheet for a pictorial 

representation of the menu functions. 
The 

ChromaFlood and ChromaBatten

 have mounting brackets 

making them ideal for floor, wall, ceiling or rig mounting. 
The

 ChromaFlood

 picture at the top of this page shows the 

mounting brackets arranged for floor mounting. 

ChromaFlood and ChromaBatten

 have a colour code letter.  This 

signifies the finished colour of the fixture (B = Black, S = Silver). Other 
colours may become available - please check with Pulsar if required. 
The 

ChromaFlood and ChromaBatten 

have a thermal 

management system.  This progressively reduces the power to the 
LEDs if the internal temperature exceeds limits set by the software. 

Excess temperature will occur if the units are exposed to high 
ambient temperatures or inadvertently covered.  It is therefore 
important for maximum performance that they have good ventilation 
on all sides. 
The lenses shipped with the 

ChromaFlood and ChromaBatten

 

may be easily changed.  Currently 5 (ChromaFlood100 only), 8, 25, 
45, 12x25 (elliptical) and 10x90 (elliptical) lens plates are available for 
the 

ChromaFlood

 with 10, 25 and 45 degree lenses available for the 

ChromaBatten

Other lenses may become available, please contact 

Pulsar

 or see 

www.pulsarlight.com

 for details 

NB - Patents applied for 

Mains Supply

 - The 

ChromaFlood and ChromaBatten

 work 

correctly on any mains voltage from 100-240 VAC, 50-60Hz, (self 
adjusting).  Power consumption is 200 Watts max. 
A 5m, bare ended, mains cable is provided.  The bare end of the 
cable should be fitted with a suitably approved and rated mains plug.   
Note: in some countries it is a requirement that such a plug be fitted 
by a qualified electrician. 

CABLE COLOURS

 

Green/Yellow = 

Earth / Ground 

Brown = Live / Phase / Hot 

Blue = Neutral 

WARNING - THIS APPLIANCE MUST BE EARTHED 

For safety we recommend the use of a Residual Current Circuit 
Breaker.  An RCCB MUST be used when powering a 
ChromaFlood or ChromaBatten in wet environments. 

PMX/DMX In/Thru 5 Pin XLR Connectors

 

Digital Control Signals:

 Two 5 pin XLR connectors on 5m cables 

(in/thru) are provided.  The pin connections of the sockets are: 

PMX (RS232/423) SIGNAL 

DMX SIGNAL 

Pin 1 = Screen / Chassis Earth   

Pin 1 = Screen / Chassis Earth 

Pin 2 = Signal 

(Blue) 

Pin 2 = Signal 

-

 

Pin 3 = Signal Earth 

(White) 

Pin 3 = Signal 

+

 

Pin 4 = no connection 

(Green)  Pin 4 = no connection 

Pin 5 = LVS (male only) 

(Red) 

Pin 5 = LVS (male only) 

Wet / Damp Environment Use

 – these products are IP65 

rated.  However, the cable connections 

must

 also be 

contained in a dry, low humidity, environment as water and 

vapour will travel inside the cables from the connection joints into the 
fixture.  A waterproof connection box, or properly fitted IP68 rated 
connectors, are essential for cable connections in such 
environments.  Suitable connectors are available from Pulsar. 

Failure to take these precautions invalidates the guarantee.

 

CONNECTIONS 

SPECIFICATION 

SPECIFICATION 

CHROMAFLOOD 

CHROMABATTEN 

Содержание Chromabatten CBAT100

Страница 1: ...ChromaFlood and ChromaBatten have a colour code letter This signifies the finished colour of the fixture B Black S Silver Other colours may become available please check with Pulsar if required The ChromaFlood and ChromaBatten have a thermal management system This progressively reduces the power to the LEDs if the internal temperature exceeds limits set by the software Excess temperature will occu...

Страница 2: ...he UIM then select 6 or 12 way using the ñ or ò keys When the required chase pattern way number shows in the display press the ü Yes key to save changes or X Back key to restore the previous settings Channel 10 may be set as a Grand Master for the 36 RGB channels only OR as a Global Grand Master for the 36 RGB channels the ALL Red Green and Blue and the Chase Levels To set the required Ch 10 mode ...

Страница 3: ...store Factory Default Settings Press the X change key on the UIM then press the ü Yes key to restore defaults or X Back key to exit The factory default settings are DMX Address 1 ChromaZone Mode 46 Channel Channels per Fixture 3 CFLD 9 CBAT Fixture number 1 Chase patterns 12 Way Channel 10 Grand Master for the 36 RGBs only Input Smoothing ON Low Voltage Supply ON DMX Line Termination OFF If NoSign...

Страница 4: ...ChromaFlood100 and ChromaFlood200 Mechanical Details ...

Страница 5: ...xture 12 Blue 42 Fixture 6 Blue 2 42 Fixture 4 Blue 3 46 Channel Mode 3 Channels Fixture 6 Channels Fixture 9 Channels Fixture 1 9 as 9 Channel Mode 1 9 as 9 Channel Mode 1 9 as 9 Channel Mode 10 36xRGBGrand Master 10 36xRGB Grand Master 10 36xRGB Grand Master OR OR OR 10 Global Grand Master 10 Global Grand Master 10 Global Grand Master 11 Fixture 1 Red 11 Fixture 1 Red 1 11 Fixture 1 Red 1 12 Fix...

Страница 6: ...1 14 89 228 Rainbow Strobe 13 86 220 White Any Colour Strobe Channels 1 2 3 set colour 83 212 White Any Colour Crossover Channels 1 2 3 set colour 12 80 204 Blue Yellow Wave Reverse 77 196 Blue Yellow Wave Forward 73 188 Green Magenta Wave Reverse 11 70 180 Green Magenta Wave Forward 67 172 Red Cyan AnyCol Op Col Wave Forward 10 64 164 Red Cyan AnyCol Op Col Wave Reverse Channels 1 2 3 set colour ...

Страница 7: ...hing t Low Voltage Supply is t DMX Line Termination t VIEW Sig SET No Sig Chan Levels DMX Address n Receiving t X Change X Restore If NoSignal use t Stand Alone Sett ings View Change ChromaZone Mode nn Channels 3 6 9 10 36 42 46 3 6 FLOOD 9 BATTEN 1 12 of 12 1 6 of 6 FLD 1 4 of 4 BAT 6 Way 12 Way CH10 36xRGB GM CH10 Global GM ON Gentle Smooth OFF Fast Video ON OFF ON OFF Stand Alone Mode Last DMX ...

Страница 8: ... apparatus before lightning storms or when unused for long periods Refer all servicing to suitably qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped...

Страница 9: ...the internal temperature exceeds predefined limits When mounting the ChromaBatten300 at an angle other than horizontal it is essential that the cable end is at the lowest point and the display at the top as shown in the picture to the left This mounting arrangement locates the internal temperature sensor at the hottest point the top Failure to observe these essential mounting arrangements may resu...

Отзывы: