www.pulsar.pl
AWZ521
4
automatic return
HEATER: T 500mA fuse, damage requires fuse-element
replacement
Overload protection OLP
12V/DC: T 630mA fuse, damage requires fuse-element
replacement
HEATER: T 500mA fuse, damage requires fuse-element
replacement
Heater’s circuit specifications:
-mains supply
-output current
- on/off temperature of the HEATER output
(thermostat)
230V/AC (-15%/+10%)
0,4A max.
ton=15°C, toff=25°C (+/- 4°C)
F1 fuse
T 500mA/250V
F2 fuse
T 630mA/250V
Mechanical specifications (tab. 4).
Pcb dimensions
70 x 83 x 42 (WxLxH)
Fixing
37 x 33 (W1xL1) mounting holes x 2
Net/gross weight
0,35kg/0,39kg
Connectors
Ф
0,41÷1,63 (AWG 26-14), plug: 5,5/2,1mm (supply output)
Operating specifications (tab.5).
Operating temperature
-10ºC...+40ºC
Storage temperature
-20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insolation
unacceptable
Vibrations and impulse waves during
transport
PN-83/T-42106
2. Installation.
2.1 Requirements
The PSU module is to be mounted by a qualified installer, holding relevant permits and licenses (applicable
and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be
mounted in accordance with the 2nd environmental class, with normal relative humidity (RH=90% maximum,
without condensation) and temperature from -10°C to +40°C.
Before mounting the PSU module, perform a load balance. During normal operation, total current drawn by
the receivers cannot exceed the maximum parameters.
The module has two outputs and delivers voltages of:
12VDC/0,3A for supplying the CCTV camera
230V/AC/0,4A max. for supplying the enclosure’s heater
(the heater’s circuit is automatically switched on by a bi-metallic thermostat: ton=15°C, toff=25°C
(+/- 4°C).
As the PSU module is designed for a continuous operation and is not equipped with a power-switch,
therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user
shall be informed about the method of unplugging (most frequently through separating and assigning an
appropriate fuse in the fuse-box). The electrical system shall follow valid standards and regulations.