ML50.100, ML50.109
MiniLine
24V, 2.1A, S
INGLE
P
HASE
I
NPUT
Mar. 2007 / Rev. 1.0 DS-ML50.100-EN
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/20
10. O
UTPUT
Output
voltage
nom.
24V
Adjustment
range
min.
24-28V Guaranteed
max.
30V
At clockwise end position of potentiometer
Factory
setting
24.5V
±0.2%,
at full load, cold unit
Line
regulation
max.
10mV
85 to 264Vac
Load
regulation
max.
100mV
Static value, 0A
Æ
2.1A
Æ
0A
Ripple and noise voltage
max.
50mVpp
20Hz to 20MHz, 50Ohm
Output
capacitance
typ.
1600µF
Output current
nom.
2.1A
At 24V, see
Fig. 10-1
nom.
1.8A
At 28V, see
Fig. 10-1
Output
power
nom.
50W
Short-circuit
current
min.
3.1A
Load impedance 400mOhm, see
Fig. 10-1
max.
5A
Load impedance 400mOhm, see
Fig. 10-1
Fig. 10-1
Output voltage vs. output current,
230Vac, typ.
Output Voltage
0
0
1
2
4
8
12
28V
16
20
24
4A
2.5
1.5
0.5
3
3.5
Adjustment
Range
Output Current
Peak current capability (up to several ms)
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start
current demanding loads or to safely operate subsequent circuit breakers.
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will
be discharged and cause a voltage dip on the output. Detailed curves can be found in chapter 27.1.
Peak current voltage dips
typ.
from 24V to 16V
at 4.2A for 50ms, resistive load
typ.
from 24V to 15V
at 10.5A for 2ms, resistive load
typ.
from 24V to 10.5V
at 10.5A for 5ms, resistive load