background image

 

INSTALLATION

 

Page 6

TM-7200/TM-6200 High Resolution Digital CCD Camera

  

 

2.2.3 (b)    PULNiX Power Cables

 

If you are using PULNiX power cables, such as the 12P-02, KC-10, etc., please refer to the pin-out 
diagram. The color coded leads use Grey for Ground and Yellow for +12V DC. 

 

FIGURE 2.

 

12P-02 Interface Cable (optional)

 

Note: 

 

Make sure that the unused leads are not touching and that there is no possibility that the 
leads could short due to exposed wires. 

 

2.2.3 (c)    “K” Series Power Supplies

 

Attach the 110V line cord to the two terminals marked “AC”. Do not plug the cord into a 110V AC 
socket until later in the procedure. Next, attach the Grey and Yellow leads of the power cable to the 
Ground and 12V DC terminals respectively. Be sure to replace the plastic terminal guard on the power 
supply at this time. 

 

Note:

 

 

The “K” series power supplies are designed primarily for OEM users who will be 
mounting the power supply inside a protective enclosure. For use in exposed situations, 
the DC-12N and PD-12 are recommended.

 

2.2.3 (d)    Building Your Own Power Cable

 

Consult the pin-out for the camera purchased. Connect the Ground and +12V power leads of the PC-
12P power connector to Pin #1 and Pin #2, respectively (power must be DC regulated and of sufficient 
current to properly power the camera).

 

12P-02 Interface Cable

Pin#

Lead Color

Function

Pin#

Lead Color

Function

 

1

Gray

GND

7

Black coax

VD Input

2

Yellow

+12VCD

8

White coax shield

GND

3

Red coax shield

GND

9

White coax

HD Input

4

Red coax

Video

10

Brown

GND

5

Orange coax shield

GND

11

Blue

Int. Cont.

6

Orange coax

VINIT

12

Black coax shield

GND

1

32mm

2,000mm

±

 10mm

(2 Meters)

PC-12P (Hirose Part #10A-10P-12S/PC12P)

Flying
Leads

1

Содержание TM-6200

Страница 1: ...69 0046 Rev A TM 7200 TM 6200 High Resolution Digital CCD Camera Operation Manual...

Страница 2: ......

Страница 3: ...ications UL CE FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable...

Страница 4: ......

Страница 5: ...deo Output 8 2 2 6 Attaching the Camera Lens 9 2 2 7 Back Focusing the Lens 9 2 2 8 Auto Iris Lens Setup 9 2 2 9 Monitor Display Mode 9 2 2 10 Connectors and Cables 9 3 OPERATION 10 3 1 Modes of Opera...

Страница 6: ...ENDIX 23 5 1 Specifications 23 5 1 1 Product Specifications 23 5 1 2 Physical Dimensions 24 5 1 3 Glass Specifications 25 5 1 4 C Mount Specifications 25 5 1 5 Front End Detail 26 5 2 Spectral Respons...

Страница 7: ...ure Timing 15 FIGURE 8 Continuous Sync Output 16 FIGURE 9 Line Data Valid 16 FIGURE 10 Frame Data Valid 17 FIGURE 11 Pixel Clock 7 FIGURE 12 Signal Board top side 18 FIGURE 13 Memory Board bottom side...

Страница 8: ......

Страница 9: ...00 is designed as a basic machine vision or automated inspection imaging sensor that provides low cost image capture and storage functions right in the camera 1 2 Features High resolution 1 2 imager T...

Страница 10: ...Removal OP3 2 Gamma Adjust to 0 45 OP4 1 Glassless CCD Imager OP21 1 4 Applications The TM 7200 TM 6200 is designed as a basic machine vision or automated inspection imaging sensor It is excellent for...

Страница 11: ...ational as a system 2 1 2 Components List Please begin by checking your order against the Components List below to assure that you have received everything as ordered and that nothing has been overloo...

Страница 12: ...ns 2 2 2 a 12 Pin Connector The TM 7200 TM 6200 has a 12 pin connector for power input Pin Description Pin Description 1 GND 7 VD Input 2 12V DC 8 GND 3 GND 9 HD Input 4 Video Out 10 GND 5 GND 11 INT...

Страница 13: ...wer supply The PD 12 power supply can be connected to the PULNiX power cable via a terminal strip or directly When wiring the PD 12 power supply directly please note the following Twist the lead ends...

Страница 14: ...lace the plastic terminal guard on the power supply at this time Note The K series power supplies are designed primarily for OEM users who will be mounting the power supply inside a protective enclosu...

Страница 15: ...le Assembly 2 2 4 a 31 Pin Connector MP211 031 113 4300 Pin Signal Cable Pin Signal Cable 1 CLK OR 1 RED 17 CLK OR 1 BLUE 2 LDV GRY 1 RED 18 LDV GRY 1 BLUE 3 FDV WHT 1 RED 19 FDV WHT 1 BLUE 4 GND YLW...

Страница 16: ...he KC 10 etc The mini coaxial leads in PULNiX multi conductor cables are designed for short runs of no longer than 100 feet Note Make sure that no extraneous wires are visible which could cause a shor...

Страница 17: ...until the best image is obtained Tighten the focus ring set screws Your backfocus is now set 2 2 8 Auto Iris Lens Setup Auto iris lenses with full video input can be used with the PULNiX TM 7200 TM 6...

Страница 18: ...n although the camera is still running on its sync timing and only outputs captured video When the negative going reset pulse is applied the camera will latch the falling edge to its next horizontal d...

Страница 19: ...external pulse resetting the internal timing including the video sync The shutter speed is the same as the external pulse width but the integration delays 9H from the leading edge FIGURE 3 External Pu...

Страница 20: ...g from 1 to 4 When the fast reset mode is selected the camera resets with internal VINIT timing which is latched to Hd and video output is also synchronized with internal VINIT timing without further...

Страница 21: ...and shutter in the same way as the external double pulse control mode When the external VINIT pulse is applied internal VINIT is latched to Hd and the second internal VINIT signal is delayed to set u...

Страница 22: ...should only be changed by a PULNiX factory authorized representative If FRAME MODE is required please contact PULNiX for this setting The differences between the two modes is explained below 3 1 4 a F...

Страница 23: ...pin 10 set the integration control pin 11 to low for integration Integrated video can be captured once integration control goes back to high All captured fields in this case are the same fields With t...

Страница 24: ...al line driven 10 bit parallel signal with EIA 422 format 100 output termination impedance Output from 31 pin connector Mating connector Airborne MP211 031 113 4300 Please consult digital cable inform...

Страница 25: ...Data Valid and FDV Frame Data Valid are kept low and restart upon the completion of integration When F1 is kept high the camera outputs odd field data otherwise even field data is output FIGURE 10 Fra...

Страница 26: ...12 Signal Board top side Set W1 AGC MGC Right MGC Manual Gain Set W2 GAMMA Left 1 Gamma 1 0 Set W3 DV AV Left DV Direct analog right Set W4 Video R S Left R Set W5 N P Open N Set W6 FRM FLD Open FLD S...

Страница 27: ...e 19 3 2 2 Memory Board FIGURE 13 Memory Board bottom side Set W1 FLD Left R Set W2 HD Left R Set W3 VD Left R Set W4 P N Open N Set W7 MFM1 2 Open 2 Set W8 FM FL Open FL VR1 A D VREF VR2 D A VREF J3...

Страница 28: ...OPERATION Page 20 TM 7200 TM 6200 High Resolution Digital CCD Camera 3 2 3 Power Board FIGURE 14 Power Board VR1 EXT VD PHASE VR2 PLL VR1 VR2 J3...

Страница 29: ...se contact a PULNiX representative 4 1 1 Symptom No Video Remedies Check that the following are properly connected and operational Power supplies Power cables Main power source Shutter control Async m...

Страница 30: ...d Support Resources For further information and support Phone 408 747 0300 800 445 5444 800 3 PULNIX 24 hour message access Fax 408 747 0660 E mail pulnixapps aol com Mail PULNiX America Inc Sales Dep...

Страница 31: ...clock 14 31818 MHz 14 18750 MHz Horizontal frequency 15 734 KHz 15 725 KHz Vertical frequency 59 94 Hz 50 00 Hz TV resolution 570 H x 485 V lines 560 H x 575 V lines Video output Analog 1 0V p p comp...

Страница 32: ...ion Digital CCD Camera 5 1 2 Physical Dimensions FIGURE 15 Physical Dimensions PULNiX 130 mm 142 7mm 118 mm Remote 32 mm 42 mm C mount 25 mm SQUARE PATTERN M2 4X 1 4 20 UNC 2B REMOTE HEAD PULNiX 8 mm...

Страница 33: ...dditionally the shorter Flange Back Length allows for reduction of the effective diameter of the first lens and reduces the number of lens elements The common C Mount lens is completely compatible wit...

Страница 34: ...APPENDIX Page 26 TM 7200 TM 6200 High Resolution Digital CCD Camera 5 1 5 Front End Detail FIGURE 18 Front End Detail Front End C Mount Ring 18 20 1 00 CCD Imager Image Plane 1 41 16 8...

Страница 35: ...t End Assembly 5 2 Spectral Response FIGURE 20 Spectral Response PIN 1 2X MOUNTING HARDWARE I C GASKET FILTER C MOUNT RING FRONT END 3X C MOUNT RING LOCKING SET SCREW 400 500 600 700 800 900 1000 1100...

Страница 36: ...28 TM 7200 TM 6200 High Resolution Digital CCD Camera 5 3 Block Diagram FIGURE 21 TM 7200 TM 6200 Block Diagram TIMING GENERATOR CDS A D MEM D A ASYNC GEN MEM CONTROL SYNC ADD RS 422 SYNC GEN CCD Digi...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...Industrial Products Division PULNiX America Inc 1330 Orleans Drive Sunnyvale CA 94089 Tel 408 747 0300 Tel 800 445 5444 Fax 408 747 0660 Email imaging pulnix com www pulnix com...

Отзывы: