LED SMT Reflow Oven T-960e
http://www.tech168.cn
5
When the status indicator lamp shows green, it indicates
that the program is running status; when the status
indicator lamp shows red, it indicates that the program is
setting status.
(tips: if the lamp changes from green to red when
the machine is in running status, press F5 into the running status
again).
Operating Instructions
1. Enter into the setting interface when starts the machine. Press F2 button to select the
wave, press F1 to select the point, press F3/F4 to set the corresponding temperature
zone up and down, press F5 goes to the heating interface.
2. Five red switches separately control the upper 1/down 1/upper 2/upper 3/down 2
temperature zones.
3. When the temperature gets to balance, open the Motor switch and adjust the
conveyor belt speed.
4. Press F2 stop heating, and enter into the setting interface.
5. Each temperature wave purposes as follows:
Wave one and two: use the same with soldering the less lead paste, like 85Sn/15Pb
70Sn/30Pb
Wave three and four: use the same with soldering the more lead paste, like 63Sn/37Pb
60Sn/40Pb.
Wave five and six: use the same with soldering high-melting-point lead-free paste, like
Sn/Ag3.5
;
Sn/Cu.75 Sn/Ag4.0/Cu.5 Sn95.5/Ag3.8/Cu0.7