LED New Light Source Reflow Oven T-960

 

 

                                                           

 

 

3. The instruction of the connecting line 

L1

L2

L3- Firewire

 

N-Zero wire 

PE- Earth wire 

 

(380V lines connection) 

 

(220V lines connection) 

Operating Instructions 

1. Enter into the setting interface when starts the machine. Press F2 button to select the 

wave,  press  F1  to  select  the  point,  press  F3/F4  to  set  the  corresponding  temperature 

zone up and down, press F5 goes to the heating interface. 

2.  Five  red  switches  separately  control  the  upper  1/down  1/upper  2/upper  3/down  2 

temperature zones. 

3.  When  the  temperature  gets  to  balance,  open  the  Motor  switch  and  adjust  the 

conveyor belt speed. 

4. Press F2 stop heating, and enter into the setting interface. 

5. Each temperature wave purposes as follows: 

Содержание T-960

Страница 1: ...LED New Light Source Reflow Oven T 960 LED New Light Source Reflow Oven Model T 960...

Страница 2: ...room temperature 3 Intelligent temperature wave heating type oversized capacity wave selection have eight temperature waves can satisfy various welding technological requirements 4 Use programmable te...

Страница 3: ...ed to connect with the PC can watch the whole repairing process very clearly 11 Ergonomic design practical and easily operated Good build quality but at the same time light weight and a small footprin...

Страница 4: ...e distribution deviation 2 Overall dimensions 1450 630 470 Machine weight 160KGS Main parts Complete machine 1 Power line 1 User manual 1 Description of the main parts 1 Welding table main body 2 Cont...

Страница 5: ...button to select the wave press F1 to select the point press F3 F4 to set the corresponding temperature zone up and down press F5 goes to the heating interface 2 Five red switches separately control...

Страница 6: ...ng technological requirements select the proper wave 2 Heating temperature regions distribution of upper three areas and the lower layer 2 areas corresponding heating waves of the first section third...

Страница 7: ...tual and the setting temperature warming slope and the peak temperature should be accordant Before the temperature reaches 160 please control the heat up speed in about 1 S If heat up too quickly the...

Страница 8: ...ncrease or reduce the temperature And let the PCB pass the system a gain until reach the reflow critical point Then turn to step 4 only when there is reflow that is good 4 If there is no reflow please...

Страница 9: ...heat range is over the reflow temperature too high should increase the transmission speed or reduce the set temperature The detailed operation is opposite to step 4 Equipment Installation 1 Set up fi...

Страница 10: ...ll the parts especially the net belt position Cannot make it be lock or fall off 4 6 Ensure the machine is stable not lean or instable Adjust the leg under the machine to keep the transmission horizon...

Страница 11: ...ly and normally At the same time when turn on the machine check the parameters are the same to the last time turn off When turn off the machine do not let the transmission belt in the hot area please...