LED New Light Source Reflow Oven T-960
4
3. The instruction of the connecting line
L1
、
L2
、
L3- Firewire
N-Zero wire
PE- Earth wire
(380V lines connection)
(220V lines connection)
Operating Instructions
1. Enter into the setting interface when starts the machine. Press F2 button to select the
wave, press F1 to select the point, press F3/F4 to set the corresponding temperature
zone up and down, press F5 goes to the heating interface.
2. Five red switches separately control the upper 1/down 1/upper 2/upper 3/down 2
temperature zones.
3. When the temperature gets to balance, open the Motor switch and adjust the
conveyor belt speed.
4. Press F2 stop heating, and enter into the setting interface.
5. Each temperature wave purposes as follows: